Regulations ch 11 Flashcards
What if a civilian makes allegations of lost, missing, or possibly stolen private property, and no chief is on scene
Dispatcher must be immediately notified to have a BC respond. Neither Officer should make any further independent investigation beyond ascertaining info req’d to complete Form BF-26. Do NOT interview witness
Who shall be responsible for the proper opening of apparatus doors
OOD shall designate a member, other than the house watchman
Off shall not converse w/Chauffeur except “SIR”
Turning corners w/rig- no rig should be driven in excess of _ mph
Speed of rig, Info received by radio, Route to be taken
15 mph
When responding to alarms can rig use one way streets against traffic for more than one block
Can one rig pass another rig going in the same direction
Only when absolutely necessary & a full stop shall be made before entering an intersection
Only if signaled to do so by OIC of rig ahead
T/F When other than 1st to arrive on the initial alarm for a fire in a Hi-Rise, Off shall direct Chauffeur of Hi-Pressure pumper to position rig at a hydrant location in proximity to a Siamese for the building
True
Members below the rank of lieutenant shall carry _
When operations are completed, OIC must have premises safeguarded by members until turned over to “POOR”
Hose spanner, door chock, & hose strap
PD, Owner, Occupant, Responsible person
A) If it’s alleged that property was taken by FD employee
B) If fire has been designated as 10-41 (all codes)
C) If complainant does not fall w/in A or B, advise complainant to notify
A) Notify IG
B) Fire Marshall & IG’s office
C) PD
A) Theft of property in connection w/illegal entry of quarters must be reported immediately to _
B) If False Alarm involved w/qtrs notify
C) If NO illegal entry of qtrs & Dept employee suspected immediately notify _
PD- Illegal entry of quarters report (Form BP-153) must be forwarded by Off to Chief of Ops.
B) Fire Marshalls
C) IG & forward report w/full particulars to Chief of Ops
Lost Dept property at Fire/Emergency Operation- If suspect is a civilian notify _; if Dept member is suspected notify _
PD; IG
Ladder companies responding to 2nd or greater alarms when ordered to roof of fire bldg or to adjoining/adjacent roof include “HULL”
Hose roller, Utility rope, LSR, Life belt
If a FF requires medical treatment as a result of respiratory injuries while operating w/a donned facepiece, what shall be done
Med Officer immediately summoned to scene to examine FF (Med Off forwards a report to Bureau of Ops), Mask & Cylinder impounded & forwarded w/o delay along with mask record card to Div of Safety. BC in immediate command at time of injury conducts an investigation
What shall be done when a FF suffers an injury to an area of the body which is covered by PPE intended to prevent such an injury & it’s severe enough to cause medical leave?
Item/clothing placed OOS & tagged w/Name, Unit, Date, Type of Injury. Immediately upon return to quarters OOD shall notify Div of Safety & be guided by instructions
Can a FF climb an AL in an unsupported position
No one shall be permitted, except in an extreme emergency where operations cannot otherwise be accomplished
Ladder pipe inoperable from base: with water flowing & a FF climbing the ladder, the correct angle of the ladder will be that when horizontal distance between _
Tip of the ladder & center of turntable is between 15-25’ (70-80 degree angle)
Ammonia refrigeration systems: HL connected to siamese connection or inlet with volume of water depending on pipe 1 1/4” - 2 1/2” require volume _
100-700 GPM