17-01 Flashcards

1
Q

Who determines if PPV is appropriate.

A

The IC in consultation with the Ventilation Sector Officer will determine if PPV is appropriate and ensure all personnel are informed.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

The Ventilation Sector Officer will

A
  • Ensure the the PPV is adequately monitored and performed safely
  • Must control the opening of the exit and entry points and must have adequate communication with the fan operator and the exit person(communication ideally made face-face)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Placement of the fan?

A

During fire operations, the PPV fan should be placed on the unburned side of the fire.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

When can the fan be turned on?

A

The PPV shall not be turned on until personnel are ready to make entry with a charged line, and an exit opening has been made.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

The exit opening location?

A

The ventilation exit opening should ideally be located as close to the fire as possible. (PPE and SCBA shall be worn)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Effects of PPV and Adverse conditions

A

The IC should contact interior personnel to determine the effects of PPV. Adverse conditions resulting from PPV should be reported immediately to the IC.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

PPV is not recommended under the following conditions.

A

1-Potential for backdraft
2-Potential that ventilation may suspend combustible dust.
3-Potential of an explosive environment
4-Defensive exterior attack
5-Attic Fire
6-When the fire has broken through the wall interior cladding. i.e. drywall, panelling, lath and plaster, and involves the structure itself.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly