TS one hour and less actions Flashcards

1
Q

LCO 3.1.1, SDM
MODE 2 with keff < 1.0,
MODES 3, 4, and 5.

A

Initiate boration to Restore within 15 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

LCO 3.1.4 rod group alignment

A

One or more rods inoperable, verify SDM with COLR or intiate boration within one hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

LCO 3.2.3 AFD

A

If not within COLR limits, reduce power to <50% within 30 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

LCO 3.4.2 RCS min temp for criticality

A

One or more RCS Tave <550F
Be in MODE 2 with
keff < 1.0. within 30 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

LCO 3.4.3 Pressure temp limits of PTLR

A

Restore parameters within 30 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

3.4.10 Pressurizer Safety Valves

A

If one inoperable, restore within 15 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

3.4.11 Pressurizer Power Operated Relief Valves (PORVs)

A

One or more PORV inoperable, close block valve and remove power if not capable of cycling the PORV.
Within one hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

LCO 3.4.17 Each RCS hot and cold leg loop isolation valve shall be open
with power removed from each isolation valve operator.

A

Remove power if one energized within 30 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

LCO 3.5.1 Four ECCS accumulators shall be OPERABLE.

A

One accumulator inop for any reason other than boron, restore within one hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

LCO 3.5.4 The RWST shall be OPERABLE.

A

Inoperable for reasons other than boron or temperature, one hour to restore

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

LCO 3.6.1 Containment shall be OPERABLE.

A

Restore within one hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

LCO 3.6.2 Two containment air locks shall be OPERABLE.

A

If one inoperable for any reason, verify a door closed within one hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

LCO 3.6.4 Containment pressure shall be  -0.1 psig and  +1.0 psig.

A

Restore containment
pressure to within
limits within one hour

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

LCO 3.6.8 Two containment sumps shall be OPERABLE.

A

One or more
containment sump(s)
inoperable due to
containment accident
generated and
transported debris
exceeding the
analyzed limits.
Initiate action to
mitigate containment
accident generated and
transported debris immediately

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

LCO 3.7.14 The spent fuel pool water level shall be  23 ft over the
top of irradiated fuel assemblies seated in the storage
racks.

A

If not, suspend movement of irradiated fuel immediately

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

LCO 3.7.15 The spent fuel pool boron concentration shall be  300 ppm.

A

If not, suspend movement of irradiated fuel immediately

17
Q

LCO 3.7.2 Four MSIVs and their associated actuator trains shall be
OPERABLE
Two MSIV actuator
trains inoperable on
the same MSIV.

A

Declare MSIV inoperable immediately