Primary sampling system Flashcards
Primary samples cooled by ____.
How many samples can be drawn at one time?
CCW
Only one, CCW runs in series to coolers so only one cooled at a time
What is the purpose of the delay coil? Which sample points have delay coils?
Provides >45 second transit time to allow decay of short lived isotopes, especially N16.
Type B, means has contact with core, delay coil in containment, RCS hot and cold legs.
What sample points are isolated on SI/phase A isolation?
RCS hot and cold legs
PZR liquid and vapor space
Accumulators
Post hydrogen monitor
SG blowdown
Cntmt air sampling valves
RF sump
What components are affected by loss of IA?
Same as Phase A/SI except the post accident h2 monitors not affected.
What are the three modules of the 1PS25J?
Reactor coolant liquid sample module
Demin liquid sample module
Radwaste liquid sample module
Post hydrogen sample monitor is required to be activated within ____ minutes following_____.
30 minutes
SI
The only two points sampled at the demin liquid module are ___ and ___.
SI accumulators
LDHXs
Arrangement of the Hydrogen monitor isolation solenoid valves is such that on a loss of a DC bus, _______.
one train will remain in service because one valve in each flow path fails as is.
Why are the post accident hydrogen monitors left continually in standby?
To meet the NUREG activation time requirement of 30 minutes after an SI in conjunction with the needed warm up time (10-20 minute) for proper operation.
What are the limits for Xe and I for LCO 3.4.16?
Xe-133 <=603 uci/gm
I-131 <=1.0 uci/gm