Containment Flashcards

1
Q

Operational design basis of containment: (4 items)

A

Max internal pressure 50#
Max internal test pressure 57.5#
Max external pressure @-3.5 #
Max internal temp = 280F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Design basis accident is _____.
Peak containment pressure ____.

A

Double ended guillotine shear of a cold leg.
U1 42.8#
U2 38.4#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Purpose of containment

A

To contain fission products and other radioactive material and prevent their release to the environment under normal and abnormal conditions.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Electrical penetrations are pressurized with ______.

A

Nitrogen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the purpose of the primary shield wall?

A

Forms the reactor cavity, acts as biological shield, and provides support to reactor vessel.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

10CFR50.67 guidelines

A

For 2 hours at the Exclusion boundary
-25REM whole body
-300REM thyroid
For entire passage of the cloud at LPZ boundary
-25 REM whole body
-300 REM thyroid

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How can we limit the pressure rise in containment from a faulted steam generator?

A

AF flow must be isolated within 30 minutes to meet containment temp and pressure criteria

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How many TS containment pressure sensors?
What functions do they control?

A

4-934, 935, 936, 937
1. Hi alarm at 0.8#
2. SI on 2/3 >3.4#
3. MSIV isolation on 2/3 >8.2#
4. CS actuation 2/4 >20#
5. Phase B 2/4 >20#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What causes a CVI signal?

A

Any SI
Manual Phase A
Hi rad (AR11/12)
Manual Phase B/CS actuation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What valves are closed by CVI?

A

(All start with 1 or 2VQ)
001a/b purge supply
002a/b purge exhaust
003 post loca purge
004a/b mini purge supply
005a/b/c mini purge exhaust

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

1PR0011A and B are the ______

A

Particulate and gaseous radiation monitors

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Equipment hatch is sized for _____

A

Passage of the reactor vessel upper head sealing O ring during refueling operations.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What is the design temperature of containment?

A

280F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Basis of low pressure limit____
Basis of high pressure limit____

A

Inadvertent Containment spray actuation

DBLOCA

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Basis for high containment temperature limit_____

A

Maintain containment <280F after SLB

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Emergency exit through emergency personnel hatch – used ______ and located_____.

A

during outages for access to containment from the containment access facility

17
Q

Unit 1 is at 99.7%. A small break LOCA occurs, resulting in a reactor trip and SI. What is response of VP chilled water system?

A

WO containment isolation valves close on the Phase A.
WO Pumps trip on WO valve position.
VP chiller trips on low WO flow.
1sx114a/b and 112a/b close
1sx147a/b open