Containment Flashcards
Operational design basis of containment: (4 items)
Max internal pressure 50#
Max internal test pressure 57.5#
Max external pressure @-3.5 #
Max internal temp = 280F
Design basis accident is _____.
Peak containment pressure ____.
Double ended guillotine shear of a cold leg.
U1 42.8#
U2 38.4#
Purpose of containment
To contain fission products and other radioactive material and prevent their release to the environment under normal and abnormal conditions.
Electrical penetrations are pressurized with ______.
Nitrogen
What is the purpose of the primary shield wall?
Forms the reactor cavity, acts as biological shield, and provides support to reactor vessel.
10CFR50.67 guidelines
For 2 hours at the Exclusion boundary
-25REM whole body
-300REM thyroid
For entire passage of the cloud at LPZ boundary
-25 REM whole body
-300 REM thyroid
How can we limit the pressure rise in containment from a faulted steam generator?
AF flow must be isolated within 30 minutes to meet containment temp and pressure criteria
How many TS containment pressure sensors?
What functions do they control?
4-934, 935, 936, 937
1. Hi alarm at 0.8#
2. SI on 2/3 >3.4#
3. MSIV isolation on 2/3 >8.2#
4. CS actuation 2/4 >20#
5. Phase B 2/4 >20#
What causes a CVI signal?
Any SI
Manual Phase A
Hi rad (AR11/12)
Manual Phase B/CS actuation
What valves are closed by CVI?
(All start with 1 or 2VQ)
001a/b purge supply
002a/b purge exhaust
003 post loca purge
004a/b mini purge supply
005a/b/c mini purge exhaust
1PR0011A and B are the ______
Particulate and gaseous radiation monitors
Equipment hatch is sized for _____
Passage of the reactor vessel upper head sealing O ring during refueling operations.
What is the design temperature of containment?
280F
Basis of low pressure limit____
Basis of high pressure limit____
Inadvertent Containment spray actuation
DBLOCA
Basis for high containment temperature limit_____
Maintain containment <280F after SLB