Power range nuclear instruments Flashcards
The PR NIs utilize what type of detector?
Uncompensated ion chamber
Which radiation detectors operate in the Ionization region?
SR, IR, and PR
MIDS
VCT cubicle and CNTMT high range monitors
Detector current comparator drawer is powered from ______. Loss of power defeats the ________ switches.
The ________ switches are unaffected by the loss of power and are still functional.
AC bus 114
Upper and Lower section defeat switches
Rod stop and power mismatch switches are unaffected.
To calculate delta I, _____- _____.
Upper minus lower
If instrument power is lost, the lights on the PR drawer will ______ and if control power is lost, the lights will _____.
Remain lit
Go dark
What is the function of the Rate mode selects switch?
Resets the positive rate trip. >5% in <=2 seconds
What is the function of the power mismatch bypass switch?
Removes the selected channel from the rod drive and U2 SG level circuitry.
What is the function of the Rod stop bypass switch?
Removes the selected channel from the rod stop circuitry and generates alarm.
What is the function of the channel comparator defeat switch?
Defeats the 3% deviation alarm function by taking a channel out of the comparator circuitry.
PR uncompensated ion chamber can has an inner coating of ____.
Boron-10
Comparator and rate drawer is powered from ______. Loss of power to this drawer disables the _______ and it will not function.
AC bus 113
Comparator channel defeat switch
P6 is the _____
Inputs_____
Purpose_____
Automatic actions_____
SR permissive
1/2 IR channels>1.0E-5%, Resets 2/2 <5E-6%
Allows manual block of SR high flux trip
Automatically unblocks SR high flux trip below P-6
P7 is the _____
Inputs_____
Purpose_____
Automatic actions_____
Low power permissive
1/2 P-10 or P-13, Resets both P10and P13 clear
Unblocks 6 reactor trips above P7
2/4 RCS flow, RCP bus UF, RCP bus UV, PZR low pressure, PZR high level, 2/4 RCP breakers open
No auto actions
P8 is the _____
Inputs_____
Purpose_____
Automatic actions_____
Low flow/turbine trip permissive
2/4 PR ch. >30%
3/4 <=30% reset
Unblocks 2 reactor trips when above P8
1. 1/4 RCS low flow
2. Turbine trip
No auto actions
P10 is the _____
Inputs_____
Purpose_____
Automatic actions_____
At-power permissive
2/4 PR channels >10%, resets 3/4 PR<10%
Blocks SR high flux trip
Inputs to P7
Allows manual block of both IR and PR low flux trip
Automatically blocks SR high flux trip