SFP cooling and cleanup system Flashcards
Single train of SFP cooling designed to maintain _____F after ____ core offload. CC temp assumed _____F.
<=145.2F
1/3
<=105F
Single train maintains _____F after one full core offload.
<=165.3F
Both trains will maintain _____F following back to back refuelings, 1/3 of one core and full core from other unit.
<=141F
Minimal water level of ______ above fuel ensures sufficient depth to remove _____.
23’
99% of assumed 10% iodine gap activity from rupture of an irradiated fuel assembly.
SFP boron concentration _____ ppm.
> =300 ppm
Minimum water depth of ____ above the top of fuel during moves will ensure _____ mrem/hr.
9’
4 mr/hr
SFP hi water alarm temp ____
Cooling placed in service____
RP to start monitoring for AA___
149F
120F
95F
What cools the SFP HXs?
CC
Power supplies
U1 SFP 134X
U2 SFP 234X
Skimmer 134V
0A Purification 132X
0B Purification 131X
SFP Level Low alarm
SFP Level High alarm
424’2”
424’9.5”
U1 side leak detection locations
U2 side leak detection locations
- U1 transfer canal
SW corner of SFP
Failed fuel region
SE corner of SFP - NE corner of SFP
NW corner of SFP
U2 transfer canal
How is dewatering of SFP prevented?
- Suction <7’ below norm. water lvl
- Anti-siphon on disch. 4” below h20
- Disch.line stops 6’ > fuel
- Sluice gate drops lvl only 6’10” if opened, still 18’8” >fuel
- Leak detection system on seams
- MCB level alarm
- No drains in SFP