SFP cooling and cleanup system Flashcards

1
Q

Single train of SFP cooling designed to maintain _____F after ____ core offload. CC temp assumed _____F.

A

<=145.2F
1/3
<=105F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Single train maintains _____F after one full core offload.

A

<=165.3F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Both trains will maintain _____F following back to back refuelings, 1/3 of one core and full core from other unit.

A

<=141F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Minimal water level of ______ above fuel ensures sufficient depth to remove _____.

A

23’
99% of assumed 10% iodine gap activity from rupture of an irradiated fuel assembly.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

SFP boron concentration _____ ppm.

A

> =300 ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Minimum water depth of ____ above the top of fuel during moves will ensure _____ mrem/hr.

A

9’
4 mr/hr

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

SFP hi water alarm temp ____
Cooling placed in service____
RP to start monitoring for AA___

A

149F
120F
95F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What cools the SFP HXs?

A

CC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Power supplies

A

U1 SFP 134X
U2 SFP 234X
Skimmer 134V
0A Purification 132X
0B Purification 131X

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

SFP Level Low alarm

SFP Level High alarm

A

424’2”

424’9.5”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

U1 side leak detection locations

U2 side leak detection locations

A
  1. U1 transfer canal
    SW corner of SFP
    Failed fuel region
    SE corner of SFP
  2. NE corner of SFP
    NW corner of SFP
    U2 transfer canal
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How is dewatering of SFP prevented?

A
  1. Suction <7’ below norm. water lvl
  2. Anti-siphon on disch. 4” below h20
  3. Disch.line stops 6’ > fuel
  4. Sluice gate drops lvl only 6’10” if opened, still 18’8” >fuel
  5. Leak detection system on seams
  6. MCB level alarm
  7. No drains in SFP
How well did you know this?
1
Not at all
2
3
4
5
Perfectly