BGPs Flashcards

1
Q

Stopping (starting) an RH Pump while using RH Letdown with the RCS solid will
cause ____.

A

an inadvertent RCS pressure rise (drop) if 1CV131 is in AUTO. Place
1CV131 in MANUAL prior to stopping (starting) an RH Pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Primary and Secondary pressure shall be less than _____ whenever either Primary or Secondary Coolant temperature _____.

A

less than 200 psig
<=70F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Containment air temperature should be maintained above____

A

70F, maintains accumulators and reactor vessel above 60F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

During core reload, suspend core alts if :

A

Any SR goes up by factor of 5 after addition of any fuel assemblies
All SR goes up by factor of 2 after addition of any fuel assemblies
Any SR indicates 0.5cps during source check
ICCR indicates criticality when adding any fuel assembly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Spray flow into the Pressurizer shall not be initiated if the temperature
difference between the Pressurizer and the Spray fluid exceeds _____

A

320F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

RCS Temperature shall not be raised above_____ until at least _____ for solid water, low pressure operation.

A

160F until at least one RCP is running

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How many methods of RCS level indication must be functional and utilized prior
to draining operation below ____elevation?

A

Two, below 402’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When can RCP be secured when borating to refuel concentration? What is maximum difference between RCS and PZR boron?

A

Once complete borating, 50F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

RCS Chloride and Fluoride concentrations shall be less than _________.

A

0.15 ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Maximum boron concentration should be limited to
_____to prevent unnecessary reduction in the
response of the source range neutron flux monitors

A

2450 ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When draining RCS, maintain above ______ for shutdown risk.

A

5% pzr level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What is the temperature range for RCS head removal?

A

60-120F

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

No more than ____ fuel shipping containers on site at one time.

A

60

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What can happen if RCS pressure is maintained below VCT pressure for extended periods?

A

With RCS pressure maintained below VCT pressure for extended periods, dissolved gas accumulation should be anticipated in RCS highpoints. RVLIS should be monitored for void growth

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If VCT level is raised above the Boron Dilution Alert Alarm setpoint of ______THEN LCO 3.3.9 must be entered

A

70%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

If the pressurizer cooldown rate Tech Spec or Administrative limits are exceeded as a consequence of a thermal stratification, the ______ shall be notified for an evaluation

A

Shift manager

17
Q

How many SR channels are required to be operable with reactor shutdown and rod control capable of rod withdrawal?

A

Two Source Range Channels shall be OPERABLE anytime the Reactor is shutdown and with Rod Control System capable of rod withdrawal or one or more rods not fully inserted, per Tech Spec 3.3.1.

18
Q

BDPS is considered inoperable if ANY of the following conditions are NOT met:

A

1). All RCS Loop Stop Isolation valves must be open. 2). At least 1 Reactor Coolant Pump must be running.
3). Both BDPS Alert Alarm Bypass switches must be in the NORMAL position.
4). Both 1LT-112 and 1LT-185 must be operable.
5). VCT LEVEL 1 and 2 are selected to different channels.

19
Q

What is required if a high negative SUR is observed during shutdown? Can rods be withdrawn?

A

In the event of a sustained start-up rate more negative than - 0.2 dpm with no rod motion, any subsequent outward motion is prohibited. Control rods shall either be driven into the core, or the reactor trip breakers shall be opened.

20
Q

If plant conditions and outage work status allow, RCS temperature should be maintained as low as possible, but greater than ____. The reason is____.

A

> 70F, to increase the margin to boiling

21
Q

RCS cooldown rate limit ______
PZR cooldown rate limit_______
PZR heatup rate limit_____

A

100F/hr
200F/hr
100F/hr

22
Q

IF Seal Injection flow is lost with RCS temperature above ____, ________ shall be maintained.

A

150F
CC through the RCP thermal barriers

23
Q

IF Component Cooling flow to the RCP Oil Coolers is lost for any reason during RCP operation, the RCPs shall be stopped before motor bearing temperature reaches _____ or Lower Radial pump bearing temperature reaches _____.

A

motor temp 195F
lower radial pump temp 225F

24
Q

a. MAINTAIN at least 1 Reactor Cavity Vent Fan ON whenever RCS temperature exceeds _______ to prevent___.

A

135F to prevent exposing Excore Neutron Detectors and associated cables to temperatures > 135F for extended periods.

25
Q

CRDM Fans shall be ON whenever the ____ or RCS temperature is greater than _____.

A

CRDM Coils are energized
350F

26
Q

How many condensate/condensate booster pumps should be in operation any time the startup feedwater pump is operating?

A

Two Condensate/Condensate Booster Pumps should be in operation any time the Startup Feedwater Pump is operating.

27
Q

MSIV’s should not be opened if the MSIV Valve Room temperature is _______.

A

> 120F

28
Q

If RCP shaft rotation does not occur within _____ then trip the RCP and notify _____.

A

2 seconds and notify the SM