Reactor Trips Flashcards

1
Q

Manual reactor trip

A

1 of 2 switches, operator judgement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Power range, neutron flux

A

High setpoint 2/4 PR ch >109%RTP (RTP=100%) DNB concern
Low setpoint 2/4 PR ch >25%RTP Startup accident
Can be blocked manually >P-10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

PR, neutron flux high positive rate

A

2/4 PR ch increase >5% of RTP within 2 seconds - Rod ejection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Intermediate range, neutron flux

A

1 of 2 IR ch >25% of RTP - Startup accident

Can be blocked manually >P-10

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

SR, neutron flux

A

1/2 SR ch >1.0E5 cps- startup accident

Can be blocked manually >P-6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Overtemp delta T

A

2/4 ch >132.5F (+-)penalties- DNB

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

OPdeltaT

A

2/4 delta T ch>107.2F (-) penalties- Overpower accident

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Pressurizer Pressure-low

A

2/4 <1885psig (Rate sensitive) DNB

Auto P7 block

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Pressurizer pressure high

A

2/4 Pzr pressure ch >2385 psig- loss of RCS integrity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Reactor coolant flow-low

A

2/3 rcs flow ch <90% of loop min measure flow (386000 gpm, 96500 gpm/loop),
on 1/4 loops when above P-8 Auto blockP8
on 2/4 loops when between P-7 and P-8 Auto block P7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

SGWL Low Low

A

2/4 NR level ch <18.0% (36.3%) on 1/4 SGs- Loss of heat sink

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

UV - RCPs

A

2/4 RCP buses <5268VAC for 0.7 seconds

DNB

Auto P7 block

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

UF RCPs

A

2/4 RCP buses <57.0Hz (time delay)- DNB

Auto P7 block

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Turbine trip

A

a. Emergency trip header pressure 2/3 EH P<1000#
b. Turbine throttle valve closure All 4 turbine TVs <1% open

Loss of heat sink

Auto P8 Block

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Safety injection input from ESF

A

Any SI signal- Backup, initiates reactor trip if a rx trip signal not already generated.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

RCP breaker position trip

A

2/4 RCP breakers not closed- DNB

Auto P7 block

17
Q

General warning

A

2/2 SSPS trains- Loss of SSPS

No specific general warning first out annunciator (dependent on power level).