SOG 6-09 SCB- Cleaning Flashcards
1
Q
-SOG 6-09 SCBA- Cleaning-
Using universal protection Cleaning SBCA steps (9)
A
- Remove SCBA from service
- Remove air cylinder
- install plastic cap onto air cylinder threads and wash cylinder with clean soapy water
- rinse with clean water
- Dry cylinder with clean clothes
- wipe down pack harness straps, frame, airlines and pressure reducers with soapy water
- rinse
- wipe down with complete SBCA assembly with clean dry clothes
- check SCBA for any damage as per “cylinder fill checksheet
2
Q
-SOG 6-09 SCBA- Cleaning-
Cleaning Mask mounted regulator
A
- using quick connect remove regulator and face piece
- remove regulator from the face piece mask
- remove any obvious dirt from the external surfaces with warm soapy water
- inspect inner surface of regulator assembly through regulator opening
- depressed donning / air saver switch, close Purge knob
- disinfect/ sanitize be spraying minimum 6 full pumps of disinfectant into opening
- turn regulator face down and shake excess liquid out allow 10 min contact time before rinsing
- rinse regulator with gently running tap water
- shake excess water out
- let dry
3
Q
-SOG 6-09 SCBA- Cleaning-
Perform regulator check
A
- make sure no moisture remains in air cylinder by opening valve and allowing air to escape for 2 or 3 seconds
- install cylinder onto clean SCBA
- install regulator at quick connect
- verify that the donning/air saver switch is fully depressed
- close Purge knob
- slowly open cylinder at least one full turn
- open Purge valve and observe the air flow from the regulator ensure dry
4
Q
-SOG 6-09 SCBA- Cleaning-
Cleaning SCOTT SCBA face piece
A
- disinfect/sanitize the face piece by spraying 3 full pumps of properly diluted disinfectant on the regulator side of the mask and 3 full pumps on the face side of the mask. wet entire surface, including all rubber and plastic areas, allow 10 minutes contact time before rinsing
- rinse with clean drinking water
- shake excess water off of facepiece and dry with clean soft cloth
- drying time can be accelerated using blow dryer on no heat high fan
- completely inspect all pieces before re assemling
- reinstall face piece on serviced SCBA and complete daily operational checks
- return to service