SOG 3-02 high rise fires Flashcards

1
Q

-SOG 3-02 high rise fires-

High rise fires procedure initial response shall follow

A

Procedures outlined in SOG 03-24 Structure fires

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

-SOG 3-02 high rise fires-

For high rise the first alarm responsibilities may include (8)

A
  • Determine incident location by speaking to on duty building employees
  • Access security key box taking Nessie’s sry keys and leaving the rest with a trustworthy person
  • Establish lobby sector
  • Deliver an initial message to tenet a/occupants, where lobby voice controls
  • Secure elevators to ground floor
  • Assign elevator operator, who may double as ECP during initial operations
  • bring high rise kit for potential operations
  • Where fire suspected, apparatus closest to the standpipe/ sprinkler connections should connect dry lines
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

-SOG 3-02 high rise fires-
High rise search and rescue. The IC shall ensure search and rescue is carried out with areas posing the greatest threat to life being priority. Other areas to be searched in the following priority may include (8)

A
  • suite of origin
  • fire floor hallway
  • adjacent suites
  • the suite immediately above
  • remainder of suites on fire floor
  • all stairwells in entirety
  • the floor immediately below the fire floor
  • other affected areas
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

-SOG 3-02 high rise fires-

High rise 3 tactical areas

A

Lobby, forward staging, tenant/ media relations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

-SOG 3-02 high rise fires-

High rise lobby may be used for (8)

A
  • building control/comms Center if equipped
  • instruction to tenants
  • monitoring progress
  • initial assembly/staging for crews, supply and equipment
  • staging other agencies
  • medical triage
  • crew rehab
  • distribution point for evacuated tenants
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

-SOG 3-02 high rise fires-

High rise forward staging shall be located

A

At least 2 floors below the incident.

Note ground or second floor incidents may necessitate the establishment of external forward staging

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

-SOG 3-02 high rise fires-

High rise forward staging maybe used for (5)

A
  • Staging PPE prior to entry
  • forward entry control
  • forward staging RIT
  • initial rehab area for personnel
  • initial medical triage
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

-SOG 3-02 high rise fires-

High rise tenant/ media relations area shall be

A

Established at the discretion of IC. The establishment of such shall warrant the IC designate a media relations officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

-SOG 3-02 high rise fires-

High rise safety considerations

A
  • Ensure tactics do not compromise building protection devices
  • ensure smoke is controlled
  • ensure that evacuation is controlled and evacuation routes are separate from emergency and smoke control
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

-SOG 3-02 high rise fires-
High rise, Additional Alarm response shall be initiated at the discretion of IC. Consideration should be given to additional alarms when it is obvious that the fire is progressing to the point where it has potential too (3)

A
  • Further endanger the life and safety of persons in building
  • spread horizontally on fire floor or vertically in building interior
  • break out to the building exterior with subsequent exposure threats
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

-SOG 3-02 high rise fires-

Where annunciator panel shows multiple indications

A

Floors shall be check in order from closet to ground up

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

-SOG 3-02 high rise fires-

Should personal determine elevator is safe

A

They shall use the designated elevator and shall proceed no higher that two-floors below the alarm/fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

-SOG 3-02 high rise fires-

High rise. If no problem is found on alarm/fire floor.

A

Check floors below and above. If safe consider silencing alarms

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

-SOG 3-02 high rise fires-

4 things personnel assigned to lobby sector shall ensure

A
  • mechanical ventilation shutdown
  • building smoke control
  • release of automatic door closure and exit door locks
  • fire telephones in operation
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

-SOG 3-02 high rise fires-

If an ecp moves to forward staging

A

The must remember PITs for crew already in hot zone

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

-SOG 3-02 high rise fires-

If comm is difficult consider using (6)

A

Building fire phones, bullhorns, the media, bell lines, fire personnel and apartment phones

17
Q

-SOG 3-02 high rise fires-

Evacuees should be accompanied

A

At least 3 floors below the lowest the lowest involved or safe refuge

18
Q

-SOG 3-02 high rise fires-

High rise exclusion zones

A

Should be designated by marking around the building and at least 50 meters in all directions

19
Q

-SOG 3-02 high rise fires-

It is recommended that elevated devices

A

Be set up as close to fire floor as possible for secondary means of egress for personal and occupants

20
Q

-SOG 3-02 high rise fires-

Regularly update occupants. Commence all messages

A

“Your attention pleas, this is Brampton fire and emergency services”

Say twice

21
Q

-SOG 3-02 high rise fires-

For alarm activation recommend message

A

“We are on location investigating the cause of the alarm. Please standby for further instructions”

22
Q

-SOG 3-02 high rise fires-

For smoke discovered recommend message

A

“Please remain in your suite. Don’t use the elevators. Dial 9-1-1 if you require help”

Repeat every 5 minutes

23
Q

-SOG 3-02 high rise fires-

For updates recommended messages are

A

“We are dealing with emergency on the - floor, please standby for further information”
“We are in control of a fire on the — floor. Please standby for further information”
“ we have extinguished a fire on the — floor. Please standby for further information”

24
Q

-SOG 3-02 high rise fires-

For evacuation key only the desired floors. Recommended messages

A

“People on the — floor(s) only should now leave the building using the — stairwells. Do not use elevator. People on other floors please remain in your suites. Dial 9-1-1 if you require help”

Repeat every three minutes

25
Q

-SOG 3-02 high rise fires-

High rise message when operations are completed

A

“The emergency is now over. You may now return to your normal activities”

26
Q

-SOG 3-02 high rise fires-

High rise message for false alarm

A

“ this has been a false alarm. You may now return to your normal activities”

27
Q

-SOG 3-02 high rise fires-

High rise first alarm responsibilities- determine the incident location and particulars by speaking to

A

on duty building employees and referring the the annunciator panel where available

28
Q

-SOG 3-02 high rise fires-

first alarm responsibilities- access security box taking needed keys and

A

leaving others keys with a trustworthy person

29
Q

-SOG 3-02 high rise fires-
Hose cabinet-
Where possible, use the

A

Use the fire floor hose cabinets so as not to prop open stairwell doors. Suite door closures should not be compromised