SOG 27-03 subject portable radios inspection and maintenance Flashcards

1
Q

SOG 27-03 subject portable radios inspection and maintenance

portable radios shall be ________ ________ and __________ each day

A

visually inspected and cleaned

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

SOG 27-03 subject portable radios inspection and maintenance

inspection shall include checking that the external surfaces of the radio are clean and that all external controls and switches are functional, do not

A

inspect the interior circuitry

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

SOG 27-03 subject portable radios inspection and maintenance

All external surfaces including the front cover, housing assembly and battery case shall be cleaned, when ever

A

a visual inspection reveals the presence of smudges grease and or grime

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

SOG 27-03 subject portable radios inspection and maintenance

Cleaning procedures for portable radios when grease/grime is visible

A
  • apply .5% dish detergent-water solution sparingly
  • stiff non metallic brush
  • use soft absorbent lint free cloth or tissue to remove the solution
  • dry radio
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

SOG 27-03 subject portable radios inspection and maintenance

Cleaning of the mic unit and battery contacts will be performed weekly (7)

A
  • remove the battery from the portable radio
  • one alcohol swab will be used to wipe the battery contacts
  • using another swab clean battery housing crevices, ensuring no dirt lodged between the housing and battery
  • remove g the mic unit with a screw driver
  • using a new alcohol swab clean the mic unit contacts
  • ensure all areas are dry using lint free cloth
  • to test turn on the unit to ensure connectivity has been received established
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

SOG 27-03 subject portable radios inspection and maintenance

to ensure health and safety of members

A

a disinfectant wipe should be used to swab the external surfaces of the radio and mic unit after each medical incident

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

SOG 27-03 subject portable radios inspection and maintenance

portable radio troubleshooting checklist (8)

A
  • antenna is in good condition (no visible wires, cracks, or bends)
  • battery has a charge- if unknown, replace with a new battery
  • remote microphone is securely fastened to the portable
  • remote microphone has a clean contact
  • remove remote microphone to distinguish if it is the source of the problem
    -perform a radio test with COmm without the remote microphone
  • if the problem is the remote microphone from your portable and only send in the remote microphone for replacement to communicate
    complete and attach a Fire Form Defective Report with all equipment being sent in for repair or replacement
How well did you know this?
1
Not at all
2
3
4
5
Perfectly