SOG 27-02 MSA Altair 4x Multi gas detector Flashcards
SOG 27-02 MSA Altair 4x Multi gas detector
Definition- oxygen concentration gas sensor
which measures the concentration of oxygen in ambient air, expressed on the meter in percentage
SOG 27-02 MSA Altair 4x Multi gas detector
Definition- comb/ex sensor
which measures the amount of combustible or explosive gas present in the environment. this amount is expressed in percentage of LEL
SOG 27-02 MSA Altair 4x Multi gas detector
Definition- Carbon monoxide
colorless odourless toxic gas that occurs as a result of incomplete combustion. the Altair has a toxic gas sensor which measures the quality of Carbon monoxide in the environment. this quality is expressed in PPM
SOG 27-02 MSA Altair 4x Multi gas detector
Definition- Hydrogen Sulfide Foul Smelling
- naturally occurring toxic gas that tends to collect in sewers and has been known to be artificially created as a method of suicide, the Altair has a pic gas sensor which measures the quantity of H2S in the environment. expressed as PPM
SOG 27-02 MSA Altair 4x Multi gas detector
Definition- bump check
a daily brief exposure of the monitor to known quantities of the target gasses to verify the sensor recognition of the gas and the function of the alarms
SOG 27-02 MSA Altair 4x Multi gas detector
Definition- calibration
a longer duration exposure of the detector to a known quantity of the target gases that allows the detector to adjust it’s settings to the quantity of gas
SOG 27-02 MSA Altair 4x Multi gas detector
persons that have not been trained or are unfamiliar with the operation of the MSA Altair 4x multi gas detector and the nature of the target gasses should
not operate the detector
SOG 27-02 MSA Altair 4x Multi gas detector
Detector does not provide readings
on all products of combustion
SOG 27-02 MSA Altair 4x Multi gas detector
at the beginning of each shift ensure that the detector has
been inspected following inspection guide-MSA Altair 4x multi-gas detector as per SOG 13-13
SOG 27-02 MSA Altair 4x Multi gas detector
Start the detector in _____ ____ whenever possible
clean air
SOG 27-02 MSA Altair 4x Multi gas detector
Personnel should wear ____ for any reported gas monitoring incidents
SCBA
SOG 27-02 MSA Altair 4x Multi gas detector
Consider use of the Altair 4x multi–gas detector in any medical assistant calls to rule out the presence of Carbon monoxide and other toxic gases at :(7), if abnormal reading are encountered remove all personnel from the building
- unknown
- trouble breathing
- unconsciousness
- nausea
- vomiting
- vsa
- general feelings of being unwell
SOG 27-02 MSA Altair 4x Multi gas detector
When encountering any readings out of the ordinary with unknown causes, request
the Hazardous materials team
SOG 27-02 MSA Altair 4x Multi gas detector
be sure the ____ ______ on the detector have been cleared to zero prior to entering an area to obtain gas level readings. this will ensure that the peak readings resided are accurate tot he current incident
peak readings
SOG 27-02 MSA Altair 4x Multi gas detector
when taking reading of an unknown area, move slowly to allow time for the detector to react. readings should be taken (3)___ ___ ___ to account for various ______ of the gases in relation to ambient air
above the head
waist level
and at the ground
densities