SOG 21-01 Water supply- regional source Flashcards

1
Q

SOG 21-01 Water Supply- regional source

sequence for hitting a hydrant,

A
  • obtain hydrant bag
  • remove the supply line
  • proceed past hydrant 3 meters
  • loop the hose around the hydrant
  • signal driver
  • watch hose come out of bed
  • when appartues stops attach a 65mm hydrant to a 65mm hydrant Port
  • open hydrant fully by turning the stem counter clockwis-e, flushing briefly by opening and then closing 65mm gate
  • personnel are then to remove the cap from the steamer Port (largest outlet 100mm) and attach the supply line from the apparatus to steamer port
  • when the driver request water, open the hydrant to charge supply
  • proceed along the supply line to the apparatus checking the line and couplings
  • lengths of supply line shorter than 30m must be laid flat to ensure there are no twists
  • if the situation dictated the officer in charge may electronically to utilize one or more 65mm hydrant Port instead of the 100mm steamer port
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

SOG 21-01 Water supply- regional source

Hydrant Class

A

A) Blue= 5675 L/MIN or greater
B) Green = 3780 to 5675 L/MIN
C) Orange = 1900 To 3780 L/MIN
D) Red = LESS than 1900 L/MIN