SOG 17-03 Positive Pressure Attack Flashcards

1
Q

SOG 17-03 Positive Pressure Attack

most offensive fire operations qualify for early application PPA,

A

the IC should be prepared to deploy PPA where appropriate and early in an operation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

SOG 17-03 Positive Pressure Attack

Prior to committing to a PPA operation the I should consider the following (7)

A

a) a 360 size up has been completed
b) flow-paths have been determined
c) confirm any vent enter isolate search (VEIS) operations are complete and has protected themselves and the occupants
d) fire location is determined
e) the fire does not involve the structure
f) minimum two crews on scene
g) exhaust locations have been determined

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

SOG 17-03 Positive Pressure Attack

ventilation fans should be placed at the point of entry from the

A

unburned side of the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

SOG 17-03 Positive Pressure Attack

ventilation fans should be positioned up ___ back from the entry point, the objective is to create a pressure “cone” effect around the door, this position will also allow access for crews to enter the building

A

2m

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

SOG 17-03 Positive Pressure Attack

PPA should only be continued for

A

brief duration, it is not meant to be maintained for long term

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

SOG 17-03 Positive Pressure Attack

PPA should only be commenced with all personnel

A

outside of the structure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

SOG 17-03 Positive Pressure Attack

In the simplest terms of this ventilation tactics (3)

A
  • improves the atmosphere- continue with it
  • makes no charge - review all aspects and reposition if necessary
  • worsening atmosphere - discontinue it’s use
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

SOG 17-03 Positive Pressure Attack

flow-paths is determined and preferably

A

upwind to downwind

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

SOG 17-03 Positive Pressure Attack

combining exterior water application (transitional Attack) simultaneously with a positive pressure attack is the

A

preferred tactical consideration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

SOG 17-03 Positive Pressure Attack

personnel should allow at least _______ of ventilation fan input prior to entering the structure

A

30-60 secs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

SOG 17-03 Positive Pressure Attack

An exhaust for the pressurized air shall be provided and shall be located in the fire area

A

this is generally a window, door or other opening

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

SOG 17-03 Positive Pressure Attack

the exhaust outlet if possible should be on a ratio

A

of 2:1 to at a minimum 1:1 to the entry

Exhaust outlet exposures shall be protected if required

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

SOG 17-03 Positive Pressure Attack

The exhaust outlet and backflow should provide information on the effectiveness of the PPA

A

if indicators demonstrate not enough flow (smoke flames, heat) at the exhaust or too much at the backflow, PPA should be re-evaluation or discontinued

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

SOG 17-03 Positive Pressure Attack

creating additional openings adjacent to the fire area may create additional flow paths

A

making a positive pressure attack ineffective with potential to draw the fire into all flow paths

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

SOG 17-03 Positive Pressure Attack

positive pressure fans may be used for exposures control , this is most effective with common attic either ____,____ and where separating walls may have been breached or ______,______

A

strip shopping centers, apartment complexes

plumbing, cracks

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

SOG 17-03 Positive Pressure Attack

ventilation fans can create problems if not effectively (3)

A

managed, monitored and coordinated

17
Q

SOG 17-03 Positive Pressure Attack

An exhaust should be in the burned area of the structure or the fire may

A

be pushed into an unburned portion of the structure

18
Q

SOG 17-03 Positive Pressure Attack

As a result of the positive pressure a _______ ______ effect may occur at the exhaust. this is normal and prediictable

A

blow torch

19
Q

SOG 17-03 Positive Pressure Attack

do no direct ____ _____ into a operating PPA exhaust

A

Fire stream

20
Q

SOG 17-03 Positive Pressure Attack

Before PPA ensure the environment doesn’t to contain

A

Class B chemicals or have a potential for a dust explosion