What is the primary function for maintaining 23 feet of water over the top of fuel assemblies in the SFP?

A

to remove 99% of all iodine activity that could be released from a ruptured irradiated fuel assembly

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the design features of the SFP/ SFP cooling that prevent draining the SFP?

A
  • the cooling suction is located 4’ below normal water level
  • return line ends 8 ‘ above f.a. and has a siphon break hole at 136’ 3” to prevent draining if get reverse flow
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Describe controls of SFP pumps?

include trips

What is the SFP leak detection system monitoring?

A

LVP - if power lost pump must be restarted

(SFP pump 2 trips on on Phase A)

Any leaks in the SFP liner, valves periodically opened to quantify leakage

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q
  1. What could happen if SFP temp > 120 deg and process water through demin?
  2. What could happen when transfer tube is open and a pressure differntial exists between CNMT and FHB?
  3. What way will water flow if there is a leak in the SFP Hx?
  4. Why do we minimize time running both SFP pumps in paralel?
A
  1. damage resin
  2. manometer effect Pcnmt > PFHB, Lsfp go up, Lrx cavity go down
  3. into SFP, Pccw > Psfpc
  4. pump 2 will deadhead (weaker)