Condensate Polishing Flashcards
What are the two signals that will open the Cond Polish bypass valve (FCV-230)?
- if either FCV-231 or 232 come off their open seats (Inlet and outlet of polisher vessels)
- DP > 70 psid for 10 sec accross the polisher vessels
Once signal clears the bypass valve will stop opening (and stay where it is)
What chemicals are added to:
Anion resin
Cation resin
for regeneration?
AC
- cat-ions - acid (R-Ca+ + H2SO4) -> (R-H)
- anions - caustic (R-Cl- + NaOH) -> (R-OH)
What are the main functions of the Condensate Polishing System?
Clean condensate:
- mechanical filter
- ion exchanger (remove unwanted ions)
- purify water (replaces unwanted ions with H2O)
regenerate resin:
- vessels, flowpaths and chemicals
What do we do with waste water that has > 20micromhos in the polisher regeneration process?
What do we do with waste water that has < 20micromhos in the polisher regeneration process?
nuetralize the pH and place in HCT for sample and discharge overboard
clean it for reuse in the Waste water recovery system
Can a resin bed be placed in service after it has been regened and soaked for 6 hours?
No, you must place the bed on recycle for 6 hours via the FCV-901 and sends discharge of vessel back to the Condenser.