Compressed Air Flashcards
Describe air compressors 01-04
05-06
07
Reciprocating air compressors, SCW cooled, broken
Rotary air compressors, SCW cooled, requires SCW booster pumps
Rotary air compressors, air cooled
What is preferred air dryer 01 or 02, why?
01- uses electric heaters to regen the desiccant , 02 uses just air(heat of compression) so it wastes lots of air
What in general is supplied by instrument air vs service air?
Instrument- plant valves and equipment
Service- grinders, pneumatic tools
If 07 compressor is in “lead”, what is order of compressors loading?
In “normal”
05/06 in “dual”
Lead- 07(104#), 05/06(103#), 05/06(101#)
Normal- 05/06(103#), 05/06(101#), 07(99#)
Dual- 05 and 06(103#)
What does Auto Start “enable” switch do?
What compressors does this apply to?
If compressor loses power and recovers, it will restart (if no trip conditions exist)
05 and 06
Air dryer 01 and 02 regeneration schemes?
Timed
- 01 , swaps every 4 hours
- 02, swaps every 4 min
Dew point
- 01, swaps @ -30 deg
- 02, swaps @ -14 deg
Flow path of air from PAC-05 to valves?
Aft cooler Mois sep Pre filt Dryer Receiver Filter