Radiation Monitoring System Flashcards

1
Q

What are all the Rad monitors that have automatic actions?

What are there actions?

A
  • RM-14 (plant vent NG) - starts RM-87 on overange
  • RM-17A/B (CCW) - shuts RCV-16 (tnk vent)
  • 0-RM-18 (LRW) - shuts RCV-18 (OVBD)
  • RM-19 (SGBD) - shuts BD o.c. vlvs, shifts FCV-498/499 to EDR vice OVBD
  • RM-22 (WGS) - RCV-17 (OVBD)
  • RM-23 (SGBD) - same as RM-19
  • RM-25, 26 (CR vent) - CR vent to Mode 4
  • RM-44 A/B (CNMT exh) - CVI
  • RM-51-54 (CRPS) - swaps to other units fans
  • RM-58, 59 (SFP, New Fuel) - FHBV to Iodine removal mode
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the following Rad Monitors monitoring?

0-RM-1

RM-2

0-RM-3

RM-4

RM-6

RM-7

0-RM-10

A
  • 1 - CR by rad rack
  • 2 - CNMT by personel hatch
  • 3 - oily water separator
  • 4 - CCP 3
  • 6 - NSSS
  • 7 - seal table room
  • 10 - Aux board
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What are the following Rad Monitors monitoring?

RM-11

RM-12

RM-13

RM-14 (R)

RM-15 (R)

RM-17 A/B

0-RM-18

RM-19

A
  • 11 - CNMT, Particulate
  • 12 - CNMT, NG
  • 13 - RHR hx room
  • 14 - Plant vent, NG
  • 15 - SJAE process
  • 17 - CCW process
  • 18 - LRW disch
  • 19 - SGBD sample
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the following Rad Monitors monitoring?

RM-22

RM-23

RM-24 (R)

RM-25, 26

RM-28 (R)

RM-29

RM-30, 31

A
  • 22 - WGS disch
  • 23 - SGBD disch
  • 24 - Plant Vent, iodine
  • 25/ 26 - CR Vent intake
  • 28 - Plant Vent, Particulate
  • 29 - Plant Vent, Gross on stack
  • 30/31 - CNMT Hi range (accident)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What are the following Rad Monitors monitoring?

RM-34

RM-41, 42,43

RM-44A/B

RM-48

RM-51, 52, 53,54

RM-58, 59

0-RM-60, 61, 62, 63, 64, 65

A
  • 34 - Area Monitor Plant Vent room
  • 41…- Gas Decay Tanks
  • 44 - CNMT exh to PV
  • 48 - PASS
  • 51…- CR Pressurization
  • 58 - Spent fuel area
  • 59 - New fuel area
  • 60 - TSC area monitors
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the following Rad Monitors monitoring?

0-RM-66

0-RM-67

0-RM-68

0-RM-69

RM-71, 72, 73, 74

0-RM-82, 83

0-RM-90, 92

A
  • 66
  • 67
  • 68
  • 69
  • 71…
  • 82, 83
  • 90
How well did you know this?
1
Not at all
2
3
4
5
Perfectly