Radiation Monitoring System Flashcards
1
Q
What are all the Rad monitors that have automatic actions?
What are there actions?
A
- RM-14 (plant vent NG) - starts RM-87 on overange
- RM-17A/B (CCW) - shuts RCV-16 (tnk vent)
- 0-RM-18 (LRW) - shuts RCV-18 (OVBD)
- RM-19 (SGBD) - shuts BD o.c. vlvs, shifts FCV-498/499 to EDR vice OVBD
- RM-22 (WGS) - RCV-17 (OVBD)
- RM-23 (SGBD) - same as RM-19
- RM-25, 26 (CR vent) - CR vent to Mode 4
- RM-44 A/B (CNMT exh) - CVI
- RM-51-54 (CRPS) - swaps to other units fans
- RM-58, 59 (SFP, New Fuel) - FHBV to Iodine removal mode
2
Q
What are the following Rad Monitors monitoring?
0-RM-1
RM-2
0-RM-3
RM-4
RM-6
RM-7
0-RM-10
A
- 1 - CR by rad rack
- 2 - CNMT by personel hatch
- 3 - oily water separator
- 4 - CCP 3
- 6 - NSSS
- 7 - seal table room
- 10 - Aux board
3
Q
What are the following Rad Monitors monitoring?
RM-11
RM-12
RM-13
RM-14 (R)
RM-15 (R)
RM-17 A/B
0-RM-18
RM-19
A
- 11 - CNMT, Particulate
- 12 - CNMT, NG
- 13 - RHR hx room
- 14 - Plant vent, NG
- 15 - SJAE process
- 17 - CCW process
- 18 - LRW disch
- 19 - SGBD sample
4
Q
What are the following Rad Monitors monitoring?
RM-22
RM-23
RM-24 (R)
RM-25, 26
RM-28 (R)
RM-29
RM-30, 31
A
- 22 - WGS disch
- 23 - SGBD disch
- 24 - Plant Vent, iodine
- 25/ 26 - CR Vent intake
- 28 - Plant Vent, Particulate
- 29 - Plant Vent, Gross on stack
- 30/31 - CNMT Hi range (accident)
5
Q
What are the following Rad Monitors monitoring?
RM-34
RM-41, 42,43
RM-44A/B
RM-48
RM-51, 52, 53,54
RM-58, 59
0-RM-60, 61, 62, 63, 64, 65
A
- 34 - Area Monitor Plant Vent room
- 41…- Gas Decay Tanks
- 44 - CNMT exh to PV
- 48 - PASS
- 51…- CR Pressurization
- 58 - Spent fuel area
- 59 - New fuel area
- 60 - TSC area monitors
6
Q
What are the following Rad Monitors monitoring?
0-RM-66
0-RM-67
0-RM-68
0-RM-69
RM-71, 72, 73, 74
0-RM-82, 83
0-RM-90, 92
A
- 66
- 67
- 68
- 69
- 71…
- 82, 83
- 90