CNMT H2 Recombiners Flashcards
1
Q
Purpose of H2 recombiners
A
Reduce [H2] in CNMT following accident
2
Q
Maximum set temp of H2 recombiners?why?
Minimum set temp of H2 recombiners?why?
A
1450 deg, protect recombiners
1135 deg, promote recombination
3
Q
What % [H2] is it dangerous to operate H2 recombiners?
A
4% could result in ignition of H2
4
Q
P.S. H2 recombiners
A
- …..G
2. ….H
5
Q
How does H2 recombiners work?
A
- CNMT ventilation circulates air to unit
- flow enters intake via preheater section (not actual separate heaters just hot metal from main heaters) down to flow orifice
- as flow rises it contacts convection heaters
- H2, O2 gas is heated to point of recombination into water vapor mixture
- exits mixing chamber (mixes w/cooler cnmt air)
6
Q
What two parameters used to determine H2 recombiners setpoint?
A
Pre-LOCA CNMT temp
Post-LOCA CNMT pressure