Pzr Relief Tank Flashcards

1
Q

Inputs to PRT

A

Pzr PORV’s & Saftey’s

ECCS relief valves

Misc valves stem leakoff

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Describe PRT

A

1800 ft3, carbon steel, 100 psig-full vacuum tank

Drains to RCDT

Has integral valve stem leak detection panel used to locate valves with excessive stem leakage ( red when temp > 212 deg)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Auto interlocks for PRT

Gas analyzer valves (8034A & B)

Primary water supply (8029)

N2 supply valves (8045 , 8035)

Vent hdr Press Control vlv ( PCV-472)

A

Auto close on phase A

Phase A

Phase A / maintains 2.5-3.5 psig

Closes at 10 psig PRT Press

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

All process streams into PRT?

A
  • RCS from relief/safety/leakoff
  • primary water to cool/ fill PRT
  • nitrogen for cover gas
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Precautions and limitations for PRT

A
  • don’t align gaseous radwaste system to PRT until both purged go O2
  • don’t drain and vent to atmosphere until [ O2] < 5cc/kg , unless Chem manager permission
How well did you know this?
1
Not at all
2
3
4
5
Perfectly