MFW Flashcards

1
Q

Sequence of opening steam supplies to MFP?

A

LP gov valves open first (hot reheat), not enough steam pressure to operate pump => HP gov valves open (MSS). When (hot reheat) LP has enough steam pressure, the HP will close down. At 100% power, HP closed, MFP operating off LP only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is FCV-420

Interlocks

A

Mainfeedwater long recirc valve
Discharge #1 fw htrs -> MN condenser

Used for chemistry cleanup of fw

If any FW htr outlet > 320 deg valve will shut (won’t open) to protect MN cond from water hammer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What gives FWI signal?

A
SI
P-14 (Ls/g > 90% NR)
   - turbine Trip
   - MFP Trip
   - FWIV's
   - FRV and Byp 

P-4 w/ Tave < 554
- FRV and Byp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How do you reset FWI signal (3)

A

Reset SI
Cycle RTB
Reset FWI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Precautions and limitations for MFW (3)

A
  • ensure > 2% Rx power before roll MFP
  • ensure fw cut into fw htr before extraction stm
  • any perturbation in condensate will affect MFP, FRV, Ls/g
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How are MFP protected from overheating during low flow conditions?

A

FCV-53 and 54 open to provide minimum recirc to condenser of 1000 gpm

Pump running for recirc valve to open (>60 d/p)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Steam sources to #1FWHtrs (3)

A

-HP turbine 3rd stage extraction
-MSR HP drain tank
-MSR excess steam vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What happens to FWH #1 on a hi hi level (2)

A

-Trip closed MSR HP drain tank drips
-vent air supply to non-return valves from 3rd stage HP ext steam

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What actions happen if Hi level in #2HDT(1)

A

Trips closed the drips valve from the #1FWHTR

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the MFW Reg Valves and purpose(3)

A

FCV-510/520/530/540
-control S/G level via the DFWCS>30% power
-isolates on a FWI
-manual operation: reverse acting valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the MFW Reg bypass valves and purpose?(3)

A

-FCV-1510/1520/1530/1540
-controls S/G level via the DFWCS<30% power
-isolates on a FWI
-no manual operation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What are the MFW isolation valves and purposes?

A

FCV-438/439/440/441
-isolates on a FWI

How well did you know this?
1
Not at all
2
3
4
5
Perfectly