H2 Purge System Flashcards

1
Q

What is normal system l/u for H2 purge system?

When would this system be used?

A

S/D, isolated w/fan and MOV bkrs racked out

After major LOCA when H2 recombiners not available or not working and [H2] approaching 3.5%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Describe components of H2 purge system?

A

Inlet filters- clean air prior to enter CNMT
Supply fan(2)- motive force of air
HCV-145,146- allow man adjust flow (3400cfm)
CIV- MOV for CNMT isolation controlled from PASS room, valves have no auto close feature=> wtch stationed if opened
Exh filter- roughing, HEPA, charcoal, HEPA
Exh fan- motive force to plant vent
HCC-147- man adjust flow (3400cfm)

Ext recombiner flange- place to attach recombiner so CNMT not released just lower [H2] and put back in

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

P.S. For H2 purge fans

A

S-1…..F
S-2….G

Exh-1-2….H

How well did you know this?
1
Not at all
2
3
4
5
Perfectly