P & C Signals, Trips & SI's Flashcards
P-4
coincidence
inputs
Rx trip and associated bypass breaker open
RTA + BYA (P-4a) 2/2 per train
RTB + BYB (P-4b) 2/2 per train
- trips turbine
- closes FRV & bypass w/ Tave < 554 F
- seal in SI reset
- steam dumps to Rx trip mode (B)
- blocks stm dumps 3/4, arms 1/2 (A)
P-6
coincidence
inputs
IR permissive > 10-10 ica
1/2
- permits manual blocking of SR trip (105 cps)
- allows de-energizing of SR Ni’s
(provides one decade of overlap between SR and IR)
P-7
coincidence
inputs
P-10 met ( > 10% PR)
or
P-13 met ( >10% Pimp)
1/2
enables trips:
- Pzr low pressure
- Pzr high level
- RCP bkr open
- RCP bus UF or UV
- RCS loop low flow
(should not operate above 10% w/ these conditions)
P-8
coincidence
inputs
PR > 35%
2/4
Changes loss flow Trip 2/4 loops -> 1/4 loops
DNB protection
P-9
coincidence
inputs
PR > 50%
2/4
Activates Rx Trip on every turbine Trip > 50%
protects against major LR
P-10
coincidence
inputs
PR > 10%
2/4
Allows blocking:
- PR flux Trip (low) 25%
- IR flux Trip (hi) 25% equivalent
- IR Rod stop 20% (C-1)
Blocks:
- Subcooling monitor alarm
Inputs:
- P-7 (low power permissive)
P-11
coincidence
inputs
Pzr Press >/= 1915 psig
2/3
below:
- allows blocking of Low Ppzr SI
- allows blocking of Low Pstmln SI and SLI
- allows enabling of Hi rate SLI
above:
- enables Low PPzr SI
- enables Low Pstmln SI and SLI
- disables Hi rate SLI
- sends open signal to Accum isolation valves
P-12
coincidence
inputs
Tave < 543 F
2/4
Blocks all steam dump valves
(protects against uncontrolled cooldown)
(Group 1 is bypassable)
P-13
coincidence
inputs
Pimp > 10% (turbine power equivalent)
1/2
Provides input to P-7
P-14
coincidence
inputs
L S/G > 90% NR
2/3 sensors 1/4 S/G
- trips Main turbine
- trips FWP turbines
- closes FWI valves
- closes FW control and bypass valves
C-1
coincidence
inputs
IR rod stop > 20% (current equiv)
1/2
stops outward rod motion (auto and manual)
can be blocked at P-10
C-2
coincidence
inputs
PR Rod stop @ 103%
1/4
Blocks Auto & Manual outward Rod motion
Can be bypassed for testing or failed channel
C-3
coincidnence
inputs
OTAT Rod stop and runback
1% below trip setpoint
2/4
blocks auto and manual rod withdrawl
runback = 10% / min
(2400 MW/ min for 1.5 sec…..wait 28.5 sec)
(target is 203 MW, runback clears when cond clears)
C-4
coincidnence
inputs
OPAT Rod stop and runback
1% below trip setpoint
2/4
blocks auto and manual rod withdrawl
runback = 10% / min
(2400 MW/ min for 1.5 sec…..wait 28.5 sec)
(target is 203 MW, runback clears when cond clears)
C-5
coincidnence
inputs
Turbine low power < 15 % Pimp (PT-505)
1/1
Stops auto outward rod motion
C-7A
coincidnence
inputs
10% loss of load/ 140 sec
Pimp (PT-505a, 506a, PT-8)(MSS)
arms group 1 and 2 steam dumps (40%’s)
C-7B
coincidnence
inputs
50% loss of load / 140 sec
Pimp (PT-505a, 506a, PT-8)(MSS)
arms group 3 and 4 steam dumps (35%’s and 10%’s)