Digital Radiation Monitoring System Flashcards
What Rad monitors are part of the Digital Radiation Monitoring System?
- Plant Vent (RM-14, 24, 28, 87) and “” R
- SJAE (RM-15) and ““R
- CNMT exh (RM-44 A & B)
- Plant Vent Gross (RM-29)
What will be displayed if a DRMS RDU or LRP overranges?
What will be displayed if an RDU loses comunicaton with and LRP?
overrange - E.EEE+EE
loss communication - E009
What will be displayed on an RDU or LRP if detector counts less than setpoint (for 60 sec)?
the FAIL/ ACK light will illuminate and an alarm will sound
What will happen on a Hi-Rad on RM-29 (plant vent gross)
Audible alarm
alarm sent to sacramento (California Office of Emergency Services)
When would you “bypass” RM-44A and B
- RM-44 A and B actuate CVI
- energize to actuate
- loss of power (maintenance)
- if restore power, elect noise could actuate CVI
- before restore power take CVI to bypass
Amber light
Alert measured parameter has exceeded the alert set point
Red indication light
High - measured parameter has exceeded the high set point
Green indication light
Fail- low detector counts less than setpoint for 60 seconds
Blue indication light
Test- module is being tested by : check source , selected by Cal or test, test/norm
White local indication
At RDU, control mode key switch on the LRP is in the Local position
White normal
Indicates monitor is operating normally with sample flow , no alarms, no test & no purge