M/U Wtr Cntrl Flashcards
Boric acid xfr pumps flowpaths…..?
P.S……….?
Capacity……?
Interlocks….?
Recirc BAST, BAST->blender or CCP, batching tank -> BAST
1-1…..F
1-2….G
Low-37.5gpm, Hi-75gpm
Intlk- while in auto Lvct < 14% -> fast 24%-> low
Manual blend/boration-> fast integrator->low
Chemical mixing tank functions
LiOH- ph Control
Hydrazine- O2 control
H2O2- crud burst
What are these valves? What is failure pos? FCV-111A FCV-111B FCV-110A FCV-110B
111A-MUW->blender (closed)
111B-Blender->top VCT (closed)
110A-BAST->blender (open)
110B-Blender->bottom VCT (closed)
Position of......when in borate? FCV-111A FCV-111B FCV-110A FCV-110B
111A-closed
111B-closed
110A-open
110B-open
Position of......when in dilute? FCV-111A FCV-111B FCV-110A FCV-110B Controller inputs?
111A-open 111B-open 110A-closed 110B-closed Volume input, rate input
Position of......when in auto? FCV-111A FCV-111B FCV-110A FCV-110B Inputs to controller?
111A-open 111B-closed 110A-open 110B-open Lvct, RCS [B], BAST [B]
Position of......when in alt dilute? FCV-111A FCV-111B FCV-110A FCV-110B
111A-open
111B-open
110A-closed
110B-open
Position of......when in manual? FCV-111A FCV-111B FCV-110A FCV-110B
111A-open
111B-closed
110A-open
110B-open
Preferred methods to borate per AP-6 and order
Normal boration-1
8104(emergency boration MOV)-2
RWST suction-3
8471(emergency boration manual valve)-4
Possible outputs of blender?
VCT top
VCT bot
RWST
LHUTs
Bags of boric acid—–>borate RCS ?
Mix boric acid in batching tank
Batching tank—>BART
BART——->BAST
BAST——>blender(CVCS)
PWMU pumps……..
P.S.
Functions
Interlocks
1-1(F),1-2(G)
One running, one in auto, stby starts any time Makeup controller demands
Trips-low PWST lvl, O.C., thermal ovrld
Purpose/ functions MU water control system
- Add pure water to 4% boric acid to RCS for reactivity control during norm or emergency
- S/d reactor by adding 4% B.A.
- add fast enough to stay crit/sub crit as Xe decays
- have enough B.A. (14042 gal) to maintain adequate SDM