FT Spring Quiz 3 Flashcards

1
Q

Your engine company arrives first at a fully involved brownstone fire. Where should you order your handline stretched?
Select one:
a. Into the most severe exposure based on life hazard
b. Into the fire building
c. Into the most severe exposure based on fire conditions
d. Operated from the exterior until a large caliber stream is placed into operation.

A

B
(Brownstones 3.4)
The correct answer is: Into the fire building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Engine 235 is ordered to stretch the second handine at a fully involved brownstone fire. Where should the officer instruct the firefighters to stretch this line?
Select one:
a. Into the most severe exposure based on fire conditions
b. Into the most severe exposure based on life hazard
c. Into the fire building
d. Operated from the exterior until a large caliber stream is placed into operation

A

C
Into the fire building as a backup for the 1st line (Brownstones 3.4)
The correct answer is: Into the fire building

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

The placement of the second line at a fire in a high rise office building may be used for all but which one of the following?
Select one:
a. Protect the position of the first line
b. Reinforce the position of the first line
c. Contain and confine fire spread and/or prevent fire from wrapping around the core and endangering operation of the first line
d. Extinguish any fire extension of the floor above the fire

A

D
It does not mention the 2nd line going to the floor above (High Rise Office 5.4.3)
The correct answer is: Extinguish any fire extension of the floor above the fire

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

For a fully involved row frame with fire in both exposures, the first arriving engine should stretch a 3 ½” supply line for a tower ladder, and stretch the first hand line to?
Select one:
a. Into the fire building through the front door
b. The top floor of the most severe exposure
c. The front of the building and operate from the exterior until a tower ladder is in operation. Then into the most severe exposure.

A

A
(Rowframes 6.5)
The correct answer is: Into the fire building through the front door

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q
At the scene of a possible chemical suicide incident, a charged hoseline should be stretched with a fog nozzle attached. This line should be used primarily for?
Select one:
a. Vapor dispersal
b. Decontamination 
c. Fire suppression
A

B
(Haz-Mat 11 4.1)
The correct answer is: Decontamination

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q
For a fire in the cellar of an occupied taxpayer, which engine company in responsible to ensure that the sprinkler system is supplied?
Select one:
a. 2nd engine
b. 4th engine
c. 1st engine
d. 3rd engine
A

D
For all taxpayer fires, the 3rd engine is responsible for ensuring the sprinkler system is supplied (Taxpayers 7.2.3 C)
The correct answer is: 3rd engine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

At a store fire in a taxpayer, to which position should the 2nd hand line be stretched to?
Select one:
a. Into the store involved
b. Operated from the exterior into the fire building
c. Into the most severely exposed exposure
d. To the roof of the fire building

A

A
The 1st two hand lines are stretched into the store involved (Taxpayers 7.3.1 A)
The correct answer is: Into the store involved

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Stretching a 2 ½” hoseline should be considered for all but which situation below?
Select one:
a. A fully involved private dwelling
b. A wind impacted fire in a private dwelling
c. A heavy fire on the top floor in a larger style private dwelling such as a Queen Anne

A

C
For a heavily involved FIRST FLOOR fire in a larger style Private Dwelling (Queen Anne) (Private Dwellings Chapter 3 53, 5.4)
The correct answer is: A heavy fire on the top floor in a larger style private dwelling such as a Queen Anne

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

At a private dwelling fire, the Incident Commander should consider ordering an exterior hoseline operated into a cellar window to allow for a quick knockdown when there will be a delay in applying water from the interior or whenever fire conditions dictate. In this situation an Incident Commander can be considered?
Select one:
a. A Chief Officer or Acting Chief Officer only
b. A Chief or Company Officer

A

B
(Private Dwellings Chapter 3 2.6)
The correct answer is: A Chief or Company Officer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

An engine company stretching the 1st handine for a fire in the choir loft of a place of worship should stretch?
Select one:
a. A 2 ½” line through the access that provides the quickest access to the fire area
b. An 1 ¾” line through the access that provides the quickest access to the fire area
c. A 2 ½” line through the main entrance
d. An 1 ¾” line through the main entrance

A

A
(Places of Worship 6.3.1)
The correct answer is: A 2 ½” line through the access that provides the quickest access to the fire area

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q
At fires in high rise fireproof multiple dwellings, the \_\_\_\_\_\_\_\_ engine company is responsible for placing the High Rise Nozzle into operation, if this alternate strategy is needed.
Select one:
a. 6th
b. 3rd
c. 4th
d. 5th
A

D
(MD Fires 6.11)
The correct answer is: 5th

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q
When supplying water to a standpipe system at a fire on the 50th floor of a 60 story high rise office building, the recommended discharge pressure is \_\_\_\_\_\_\_.
Select one:
a. 300
b. 450
c. 350 
d. 400
A

C
(High Rise Office 4.1.7)
The correct answer is: 350

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q
In cellar and sub-cellar fires in Cast-Iron and Mill Loft buildings, if the building is supplied by a sprinkler system servicing the fire area, which engine should ensure a supply line is stretched to feed the system?
Select one:
a. 4th engine
b. 2nd engine 
c. 1st engine
d. 3rd engine
A

B
(Loft 6.2.1 B)
The correct answer is: 2nd engine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q
The cockloft nozzle is to be supplied by a \_\_\_\_\_\_\_ handline. The discharge rate of this nozzle is approximately \_\_\_\_\_\_\_ gpm.
Select one:
a. 2 ½”/ 80
b. 2 ½” / 125
c. 1 ¾”/ 80
d. 1 ¾”/ 125
A

D
(TB Tools 7, Data Sheet 18)
The correct answer is: 1 ¾”/ 125

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q
The supply inlet of the Blitzfire monitor is \_\_\_\_\_\_\_\_\_. It should not be operated at more than \_\_\_\_\_\_\_ psi inlet pressure with any type of solid stream or fog nozzle.
Select one:
a. 2 ½”/ 175 
b. 2 ½”/ 250
c. 1 ¾” /250
d. 1 ¾” /175
A

A
(TB Tools 38 7.1, 7.3)
The correct answer is: 2 ½”/ 175

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q
The Purple K Dry Chemical Extinguisher has a discharge range of \_\_\_\_\_\_\_\_\_\_\_feet and a discharge time of \_\_\_\_\_\_\_\_\_\_\_ seconds.
Select one:
a. 24-25/ 11
b. 24-25/ 21
c. 19-20/ 21
d. 19-20/ 11
A

D
(TB Purple K 2.2)
The correct answer is: 19-20/ 11

17
Q
Supplied by a 2 ½” hoseline, the high rise nozzle will produce flows of 200-250 gpm at \_\_\_\_\_ psi nozzle pressure with water flowing.
Select one:
a. 40
b. 60
c. 25
d. 50
A

D
(TB Tools 7, Data Sheet 17 4.3)
The correct answer is: 50

18
Q
When used in the portable ground base, the Akron New Yorker Multiversal Nozzle should not be operated at more than \_\_\_\_\_\_\_\_ gallons per minute with any type of straight stream or Fog Tip.
Select one:
a. 800 
b. 250
c. 500
d. 600
A

A
(TB Tools 17 3.4.5)
The correct answer is: 800

19
Q
Brush Fire Units and all Staten Island engine companies are equipped with \_\_\_\_\_\_\_ lightweight yellow forestry hose in \_\_\_\_\_\_\_\_\_-foot lengths.
Select one:
a. 1 inch/ 100 
b. 1 inch/ 50
c. 2 inch/ 100
d. 2 inch/ 50
A

A
(AUC 151 4.7.1)
The correct answer is: 1 inch/ 100

20
Q
A unit preparing to use a Bresnan Distributor for a cellar fire would be correct to connect the distributor to a \_\_\_\_\_\_\_\_\_ hose.
Select one:
a. 3
b. 2 ½” 
c. 1 ¾”
d. 3 ½”
A

B
(Evolution 13 3.6)
The correct answer is: 2 ½”