Bx Test 9 Flashcards

1
Q

The incorrect procedure when using the Positive Pressure Fans (PPF) can be found in which choice?
A: When using the PPFs, pressurize the evacuation stairwell before the attack stairwell

B: When placing PPF from the attack stairway door, the optimum position is 4 to 6 feet with an angle tilt of 80 degrees

C: One PPF can provide the proper pressure in the stairwell up to 10 stories depending on conditions, and two fans will pressurize a 40 story building when properly positioned

D: When using PPFs for negative pressurization, place PPF inside the contaminated area facing the exhaust opening 6-8 feet back and tilted up at an angle of approximately 30 degrees

A

A
Explanation:
AUC 349
In priority order:
1-Pressurize the attack stairwell
2- Evacuation stairwell
3- Public hallways…..6.5
B- 7.2
C- 7.3
D- 10.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Your unit is assigned to a 3rd alarm fire in the borough of Brooklyn. You should report to the Staging Area Manager which is?
A: BC01S

B: BC02P

C: BC04R

D: BC06C

A

B
Explanation:
S - Safety Officer
P - Staging Area Manager
R - Resources Unit Leader
C - Communications Unit Leader
Comm 2 p37 - P

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Which of the following operations was incorrect at a high rise office building fire?
A: The first arriving Engine Officer will consult with the first arriving Ladder Officer regarding the location of the fire and available stairways to properly select the attack stairway.

B: The second hoseline was stretched to protect the search and evacuation of the fire floor.

C: The attack stairway needs to be a stairway with a standpipe outlet and should not be a fire tower.

D: Due to the large, uncompartmented areas in these commercial buildings, all hoselines stretched and operated shall be 2 ½” hose.

A

C
Explanation:
***Recent update
C. The attack stairway does not need to be a stairway with a standpipe outlet. However, the attack stair should not be a fire tower.
High Rise Office 9.3.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

The members of Ladder 99 just returned to quarters from a building collapse where multiple victims with various injuries were pulled from the rubble. Members were discussing the length of time a victim could be trapped before a rescue medic must be given access to the patient. Which statement below is INCORRECT?
A: Victim A who was pinned for 45 minutes suffering minor injuries.

B: Victim B who was pinned for 75 minutes suffering minor injuries.

C: Victim C who was pinned for 15 minutes suffering serious injuries.

D: Victim D who was pinned for 30 minutes suffering serious injuries.

A

A
Explanation:
FFP COLLAPSE
A is Incorrect - If the victim has been pinned for more than one hour or appears to have suffered serious injuries, a Rescue Paramedic must be given access to the patient as soon as there is access… 11.6 pg 31…

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When operating at a Con-Edison facility involving electrical components, all of the following are correct except?
A: Handlines can be used on energized equipment if equipped with a fog tip set at a pattern 30 degrees or greater

B: The decision to apply water streams to electrical components at Con-Edison facilities will not be undertaken by first arriving units

C: The primary means of applying water to energized electrical components is through the use of a Tower Ladder

D: Salt water shall never be used for applying water streams on live electrical components

A

A
Explanation:
AUC 338
A- HANDLINES SHALL NEVER BE USED ON ENERGIZED ELECTRICAL COMPONENTS AT CON-EDISON FACILITIES ..2.1
B- Above the rank of DC…4.2
C- 5.4
D- 7.3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Immediate entry of an imminently hazardous condition can be accomplished in eCIDS how?
A: Use the eCIDS application to enter the proposed immediate CIDS and change the “CIDS type” dropdown to “Immediate”. Then notify the administrative BC by phone to inform the Chief of the pending immediate CIDS.

B: Fax a paper copy of the CD-201 to the administrative BC and email the Chief, notifying the BC of the condition and need for the pending immediate CIDS.

C: Use the eCIDS application to enter the proposed immediate CIDS and change the “CIDS type” dropdown to “Immediate”. Then notify the administrative BC by email to inform the Chief of the pending immediate CIDS.

D: Fax a paper copy of the CD-201 to the administrative BC and call the Chief, notifying the BC of the condition and need for the pending immediate CIDS.

A

A
Explanation:
A phone call is required to alert the BC if the need to approve the immediate eCIDS.
Comm 4 4.3.3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

An Officer and not less than _____ firefighters, shall perform BISP inspection activities.
A: 2

B: 3

C: 4

D: 5

A

B
Explanation:
Regulations Ch 12: 12.2.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Emergency Evacuation Devices are found in various locations throughout the subway system. Which location listed below is an INCORRECT location to find the device?
A: At underground stations, the EED is located at the first blue light location south of the southbound platform.

B: At grade level and elevated stations, the EED is located at the full-time token booth.

C: The EED is located at the base of the Emergency Exit at both ends of each under river tunnel.

D: In Staten Island, EEDs are located near Tower B, at the Saint George Rail Terminal and near the crew quarters at the Tottenville Train Yard.

A

B

Explanation:
AUC 207 – SUBWAY OPERATIONS
A – Correct – At grade and underground stations 3.1
B – Incorrect – At Elevated stations 3.2
C – Correct – 3.3
D – Correct – 3.5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

SOC Support Ladder (SSL) Companies have received basic training in Trench Rescue. At one of these incidents, it would be correct for SSL members to take each of the following actions except?
A: They shall immediately begin scene evaluation and hazard identification through the use of their air monitoring equipment.

B: They shall establish a safe zone around the perimeter of the site, with the prevention of a secondary cave-in as the prime consideration.

C: They will, if possible, begin removing the spoil pile from the danger zone if that has been identified as a problem. They shall take steps to remove unnecessary vehicles and vibrations.

D: They should ensure a stairway, ladder, ramp or other safe means of egress is located in trench excavations that are 3 feet or more in depth so as to require no more than 40 feet of lateral travel for employees.

A

D
Explanation:
A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet of lateral travel for employees.
Also…..They shall make the Incident Commander aware of the need for access for specialized rescue vehicles to the perimeter of the trench and assist in maintaining such access clear. They shall operate in full compliance with applicable OSHA regulations.
HM 10 7.4 B

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

While performing a search during a plane crash, you come across a spherical flight data recorder (Black box). From the choices listed below, what is the correct color of this flight data recorder?
A: International orange

B: Bright yellow

C: Red

D: Black

A

B
Explanation:
Spherical recorders Bright Yellow
Rectangular recorders are Red or International Orange
AUC 325 sec 6.2.3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

You’re the company officer working in Ladder 100. The apparatus was placed out of service and members have just returned to quarters with the spare. They are in the process of placing the portable ladders on the spare apparatus. Which of the following comments is correct?
A: If the ladder cannot be held securely, provisions shall be made to secure the ladder as safely as possible pending repair or relocation of ladder holding devices by on-duty members.

B: If the officer feels the ladder cannot be temporarily secured to the spare apparatus in a safe manner, and there is danger of loss of the ladder during response, the unit shall be placed out of service.

C: When ladders are temporarily fastened to the apparatus, the fastenings must be checked after each response.

D: When a ladder cannot be held securely a requisition shall be forwarded and an entry made in the office record journal.

A

C
Explanation:
A. …repair or relocation of ladder holding devices by FIRE TOOLS AND EQUIPMENT UNIT.
B. …THE LADDER SHALL BE LEFT OFF THE APPARATUS.
D. …entry made in THE COMPANY JOURNAL.

Portable Ladders Section 5

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Hydrant discs should be painted with the company number, Which disc is listed incorrectly?
A: Blue discs shall be placed on partially OOS standpipes and fully OOS sprinkler systems.

B: Yellow discs shall be placed on frozen hydrants (comes in 4 1⁄2” and 2 1⁄2” sizes).

C: Blue discs are not used on hydrants.

D: White discs shall be placed on unserviceable hydrants (comes in 4 1⁄2” and 2 1⁄2” sizes).

A

A
Explanation:
Eng Ops Ch 3 add 2 sec 2.6 and Ch 3 add 4 sec 2.4.7
Blue discs are reserved for use on partially OOS auxiliary fire protection systems (standpipe and sprinkler systems)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When operating at a three car accident on the Bronx River parkway where the estimated rate of speed is 70 mph, you instruct your FFs to place the furthest flare how many feet back?
A: 550 feet

B: 450 feet

C: 350 feet

D: 150 feet

A

A
Explanation:
Estimated rate of speed multiplied by the first digit plus 60
70 x 7+60= 550
Remember, its the estimated rate of speed. NOT the posted speed limit
Training Bulletins 8 p-6

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Two members discussing flooring in taxpayers agreed on all statements below except which incorrect choice?
A: Flooring can vary in taxpayers. The most common type floors are tongue and groove boards or plywood, supported by wood floor joists.

B: Heavy terrazzo or concrete is sometimes placed over wood joist floor construction, an exceptionally hazardous condition.

C: Paneling under display windows at street fronts can always be removed to offer ventilation and stream operation points for cellar fires. The flooring under the raised display platform is always omitted behind these panels.

D: In newer type taxpayer slab construction, concrete floors are prevalent on ground level with no basements or cellars in the buildings.

A

C
Explanation:
Paneling under display windows at street fronts can SOMETIMES be removed to offer ventilation and stream operation points for cellar fires. The flooring under the raised display platform is SOMETIMES omitted behind these panels.
B Note: A fire in the cellar may weaken floor supports with little evidence of heat conditions on the first floor. These floors are difficult to ventilate to allow early advance of cellar lines or use of cellar pipes and distributors. Sudden failure due to weight on the floor is possible.
Txpyr 3.9.1-3.9.4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Generally, what is the preferential order for removal of people from a building: **1. Interior stairs **2. Horizontal exits **3. Fire Escapes **4. Ladders **5. Life Saving Rope.
A: 1,2,3,4,5

B: 1,3,2,4,5

C: 1,2,4,3,5

D: 1,3,4,2,5

A

A
Explanation:
ACRONYMN “I HAVE FIVE LITTLE RATS”

INTERIOR STAIRS
HORIZONTAL EXITS
FIRE ESCAPES
LADDERS
ROPE

Aerial Ladders 6.7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

A white line under the number on the barrel indicates the hydrant is _________.
A: on a dead end main and is only supplied from one direction, which may limit water flow.

B: on a dead end main and is supplied from both directions, which may increase water flow.

C: on a larger than normal main and is only supplied from all directions, which will increase water flow.

D: on a larger than normal main and is only supplied from one direction, which will increase water flow.

A

A
Explanation:
Eng Ops Ch 3 add 4 sec 2.4.1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Choose the incorrect statement when operating at a Compactor/Incinerator incident.
A: For a Compactor chute fire, the first arriving engine company will proceed to the fire floor and stretch a line and operate into the chute to extinguish the fire

B: For a Compactor chute fire, the first arriving OV FF will operate with the engine company to provide access to the chute and check for extension

C: For an Incinerator fire, the first arriving engine company generally will stand fast in the lobby with SCBAs, roll ups, and standpipe kit. Officer can send members to assist the ladder company in search and vent, however, generally the officer and at least 2 men shall remain in the lobby.

D: In City Housing Projects, the chute door on the first floor may be color coded: RED for incinerator, GRAY for compactor

A

A
Explanation:
Training Bulletins Fires 7
A- One level above….8.2
B- 8.2
C- 4.1
D- 1.3

18
Q

Suspended ceilings can present a hazard to members operating at a taxpayer fire. Of the following choices, which is incorrect?
A: As many as two or three dropped ceilings may be found in a particular store. These suspended ceilings offer their own collapse potential when loaded with water or weakened by fire and are sometimes blown down by a backdraft in the cockloft.

B: Suspended ceilings are suspended by light wood strips, steel wire or steel bars, all of which are quickly affected by fire.

C: Special care must be exercised when these ceilings are constructed of heavy wire lath and plaster or tin, as these ceilings often fail and fall in one piece over the entire area of a store.

D: These ceilings should not be “punched” with a hook as the multiple layers of tin, sheetrock or tiles may be brought down by such action.

A

D
Explanation:
These ceilings SHOULD be “punched” with a hook for water detection, to check construction and fire conditions. Multiple layers of tin, sheetrock or tiles may have been affixed together on supports which were not intended to carry such weight.
Also…When initially pulling suspended ceilings members should be in a safe area in case of total failure.
Txpyr 3.8.1, 3.8.2

19
Q

In old law tenements, the Ladder Company Officer must control and coordinate all ventilation tactics by the inside and outside team. Uncontrolled and uncoordinated ventilation tactics can precipitate rapid fire extension and production of large volumes of smoke, which can endanger occupants and firefighters. Which of the following ventilation tactics is incorrect?
A: Ventilation for extinguishment entails venting window(s) of the immediate fire area as the engine company is extinguishing the fire.

B: When the member on the exterior hears the notification from the engine officer to the IC that they are applying water on the fire, he/she may now ventilate the windows in the immediate fire area.

C: When members wish to perform additional horizontal ventilation away from the immediate fire area, this must be communicated and coordinated by the ladder company officer in the area prior to performing such ventilation.

D: When performing ventilation for search for a known life hazard, this action must be communicated to the ladder company officer.

A

B
Explanation:
B. Before venting the window(s) the member must communicate with and receive approval from the Ladder Company Officer.

Ladders 3: 5.7.2; 5.7.3

20
Q

Engine 99 lost their CFR status during the course of the day tour. Which of the following actions taken by the officer was MOST CORRECT?
A: The officer notified the dispatcher they were out of service and again at the change of tours when they were in service for CFR runs.

B: The officer notified the Battalion they were out of service for CFR runs.

C: The officer notified the Division they were out of service for CFR runs.

D: The officer entered the event in the company and office record journals.

A

B
Explanation:
CFR CHAPTER 2
A – Incorrect – At 0900 & 1800, unit status defaults to normal CFR status 1.8.1 Note.
B – Correct – Notify the Battalion 1.8
C – Incorrect – Companies only notify the Division when they are completely out of service. REGS CH 30
D – Incorrect – The event is only entered in the company journal. 1.8

21
Q

The FDNY has issued Air-Purifying Respirators (APR) to all field units. The APR consists of the members facepiece, Scott 40 mm facepiece adaptor with a single filter port, and Scott CBRN CAP 1 canister. In regards to the Scott CBRN CAP 1 canister, select the most correct information listed below.
A: The label is olive green and has a seven year shelf life

B: The label is raspberry red and has a seven year shelf life

C: The label is blueberry blue and has a five year shelf life

D: The label is yellow and has a five year shelf life

A

A
Explanation:
Training Bulletins add 2 sec 8.6

22
Q

Two members of a SOC Support Ladder Company were discussing OSHA regulations in regard to protecting employees from cave-ins in an excavation and were correct in which statement/s?
1. There shall be an adequate protective system (shoring) unless the excavation is made entirely in stable rock.
2. There shall be an adequate protective system (shoring) unless the excavation is less than 5 feet in depth and examination of the ground by a
competent person provides no indication of a potential cave-in.
A: Neither 1 or 2

B: Only 1

C: Only 2

D: Both 1 and 2

A

D
Explanation:
HM 10 7.4 A

23
Q

No member shall enter, leave or operate in an IDLH atmosphere unless the member teams-up with a least one other member and remains in visual or voice contact with that member. The only exception to this Federal mandated standard for the teaming of members, is when a known life hazard is found and immediate action could prevent the loss of life. This does not apply to standard search and rescue procedures. In all incidents of such individual action, the Incident Commander shall forward a report to the ___.
A: Borough Commander

B: Chief of Operations

C: Chief of Department

D: Fire Commissioner

A

B
Explanation:
Ladders 3: Page 49

24
Q

All units are 10-84 and in position for a fire in apartment 12C on the 12th floor of a 18 story 100X100 High-Rise Fireproof Multiple Dwelling (HRFPMD). Choose the unit/member in the incorrect position.
A: The FAST Unit and CFR Engine staged on the 11th floor

B: With the door to the fire apartment left open, the first arriving engine charged the hoseline before exiting the attack stairway

C: The 2nd arriving engine obtained the Post Radio from the 2nd arriving BC and brought it to the standpipe outlet where the first hoseline is being connected and established a communications link on the Command Channel 2 if necessary

D: The 1st and 3rd arriving Roof FFs brought the K.O. Curtain to the apartment directly above the fire

A

C
Explanation:
Multiple Dwellings
A- 6.6.3 staged on the floor below ready for rapid deployment when the fire is above the 6th floor
B- 6.7.3.B
C- Obtain Post Radio from 1st arriving BC …..6.8.2
D- 6.14.4, 6.16.4

25
Q

Which code below would be appropriate for a false alarm activation caused by construction in the cellar of a high rise multiple dwelling?
A: 10-35 no code

B: 10-35 code 1

C: 10-35 code 2

D: 10-35 code 4

A

C
Explanation:
10-35
No Code - Unwarranted
Codes 1-4 - Unnecessary
Code 1: alarm system testing or servicing
Code 2: construction activities
Code 3: ordinary household activities (toast, steam, aerosol spray)
Code 4: other known cause (e.g., alarms resulting from cigarette smoking in unauthorized areas). When this code is used, a NYFIRS report must be completed
Comm 8 10-35

26
Q

Members of your unit are drilling on ladder company tactics at peaked roof private dwellings. They are discussing the tactical use of both tower ladders and aerial ladders. They are also instructing the junior firefighter about proper positioning of portable ladders. Which one of the comments made by your members was correct?
A: The preferred position of the tower ladder is parallel to the front of the building, so the basket can be placed to the “valley” area where a hook ladder can be used to reach the peak.

B: The aerial ladder shall be positioned to facilitate raising and extending the ladder over the corner of the building. Extend the ladder at least 2 feet above and to one side of the peak.

C: The aerial ladder is the most versatile, efficient and safest method to ventilate the roof.

D: A portable extension ladder may be used from the porch roof to the main peak.

A

D
Explanation:
A. …so the basket can be placed OVER THE CORNER OF THE BUILDING NEAR THE PEAK OF THE ROOF.
B. …AT LEAST 5 FEET ABOVE AND TO ONE SIDE OF THE PEAK.
C. THE TOWER LADDER…

Private Dwellings Ch 4: 6.2

27
Q

You are a new Lt. detailed to Engine 7, a communications unit for the day tour. As you compile your riding list for the tour, you ponder the following statements. Which choice below is your only CORRECT thought?
A: To be in service as a communications unit, three trained members including a trained officer must be working.

B: To be in service as a communications unit, three trained members, not including the officer must be working.

C: To be in service as a communications unit, two trained members, not including a trained officer must be working.

D: To be in service as a communications unit, three trained members and a trained officer must be working.

A

B
Explanation:
ICS ADDENDUM 2 ADDENDUM 3 – COMMUNICATIONS UNIT
B is correct – 2.2 Three trained members must be working for the unit to be in service. The officer is not required to be trained to be in service.

28
Q

The only correct procedure when using an elevator during fire operations can be found in which choice?
A: Do not use an elevator in a bank which serves the fire floor if a lower bank of elevators reaches within 7 floors of the fire floor

B: If using an elevator in a bank which serves the fire floor, select a floor at least two floors below the fire floor or two floors below the lower level of an access stair in the fire area, whichever is lowest

C: No more than five members permitted in any elevator car

D: In the event the elevator car does not stop at the selected floor, a gloved hand may be used to pry the elevator car door open disengaging the car door interlock

A

B
Explanation:
Training Bulletins Emergency 1 sec 6
A- Within five floors
C- No more than six
D- A tool

29
Q

At a major “lifesaving” operation at the scene of a radiological emergency that has not been deemed a catastrophic event, how long can a firefighter operate when levels of 50 Rem/hr are detected?
A: The firefighter cannot operate

B: The firefighter can operate for one hour

C: The firefighter can operate for 30 minutes

D: The firefighter can operate for 15 minutes

A

C
Explanation:
If a firefighter reports a reading of 50 Rem/hr; the firefighter can only be exposed for 30 minutes before reaching the dose limit for an emergency exposure of 25 Rem. Ex: 50 Rem/hr x 0.5 hr= 25 Rem (dose).25 Rem is the “decision dose” for Lifesaving or Protection of Large Populations.
ERP Add 4 Table 3 and 4

30
Q

When responding to gas emergencies, gather information available from the response ticket. Construction type, occupancy, caller location and description should be combined with the responder’s knowledge of natural gas systems to increase situational awareness. Which of the following response considerations is incorrect?
A: The gas utility company is required to give an ETA, and response times are typically within 30 minutes.

B: If a strong odor is present on approach, stop and meter the area. If the meter displays a minimum of 20% or above of the LEL, this may indicate a potentially serious leak and may require treating the incident as a major gas emergency.

C: The apparatus shall not be positioned in front of the reported leak location.

D: Additional units shall stage at street corners, and only enter the block where appropriate.

A

B
Explanation:
B. 10% of the LEL…

Natural Gas 6.1

31
Q

“Venting for Search” is often required at fire operations. Of the following choices, which is incorrect regarding this procedure?
A: Prior to venting a window for access, the member must determine if the ventilation profile indicates that the area may be tenable for search and does not pose a high risk to the member.

B: Once a decision has been made and approval has been granted to enter, the member should clear out the window for access and be cognizant that a new flow path has been created.

C: Upon completion of clearing the window and before entering, reassess the smoke and heat conditions to determine if the area is tenable. If conditions now prevent access, immediately notify the Ladder Company Officer of this situation.

D: After venting and entering, the priority action for the member is to conduct an immediate search of the area for victims.

A

D
Explanation:
After venting and entering, the priority action for the member is to ISOLATE the area by closing a door BEFORE conducting the search (VEIS). By isolating the area the conditions in the room should improve as the closed door will stop the flow of fire conditions and the window will provide an exhaust vent allowing a safer and more effective search.
A Note: Members should also consider other factors, such as wind conditions, potential for auto-exposure and if there is a life hazard above your position.
C Note: If conditions are tenable, the member should reach in and probe the immediate area for potential victims.
Vent 12.6

32
Q

The FDNY has trained and equipped its Rescue companies in Dive Rescue operations. When a victim is submerged below the surface, the incident is now beyond the capability of a water rescue unit. Rescue divers will be deployed in order to recover the victim. Which of the following statements is incorrect?
A: If the victim is submerged, immediately search for a reliable witness.

B: Once located, ensure the witness keeps their reference point and visually maintains the last location where they saw the victim prior to submerging.

C: Do not allow the witness to be removed from this reference point until the arrival of the rescue company. Then have the witness report to the command post.

D: Once the last location of victim is confirmed, units on the scene shall determine the best access point for the entry of the Rescue divers.

A

C
Explanation:
C. Do not allow the witness to be removed from this reference point. KEEP THE WITNESS AT THIS LOCATION THROUGHOUT THE OPERATION.

Water Rescue 5: 2.2; 2.3

33
Q

At a fire in a high rise office building, when the SAE Group is established units assigned to the SAE Group shall switch to which channel?
A: The primary tactical channel.

B: The secondary tactical channel.

C: The primary command channel.

D: The tertiary tactical channel.

A

B
Explanation:
In this case units shall not communicate with the ICP unless urgent.
HROB 6.2.1 D1

34
Q

The Unit that is responsible to confirm the evacuation doors are closed on the fire floor in a HRFPMD can be found in which correct choice?
A: 3rd arriving ladder company

B: 2nd arriving ladder company

C: 1st arriving ladder company

D: Rescue company

A

A
Explanation:
Multiple Dwellings
1st arriving ladder CONTROLS….6.14.1
2nd arriving ladder ENSURES….6.15
3rd arriving ladder CONFIRMS….6.16.2

35
Q

Members of your unit are practicing an evolution whereby a hose line is stretched up an aerial ladder. Which choice below is incorrect regarding this procedure?
A: The turntable of the aerial ladder is placed directly below the objective.

B: Hose folds are arranged below the turntable.

C: The first member carrying hose up the ladder does so by placing the hose under the left arm with the nozzle over the right shoulder.

D: Hose is placed on the right side of the ladder as members climb.

A

D
Explanation:
Hose is placed on the LEFT side of the ladder as members climb.
Evol 22

36
Q

When relocating in the quarters of another unit, Officers shall notify the Borough dispatcher at each of the following times except?
A: When in the response district of the unit they are covering.

B: When returning to their own quarters.

C: When back in their own response district.

D: When leaving their own quarters to proceed to the relocation.

A

D
Explanation:
Acronym: RRR
Response district of relocated quarters
Returning to quarters
Response district of own quarters
Comm 8.11.6

37
Q

When operating at a Con-Edison Substation involving 345,000V, the proper safety distance can be found in which choice?
A: 10 feet

B: 18 feet

C: 30 feet

D: 50 feet

A

B
Explanation:
345,000V 18 feet
15,000-38,000 feet 10 feet
AUC 338 add 2 sec 2

38
Q

While returning from an alarm, your apparatus hits another moving vehicle. Upon arrival at the firehouse after making the proper notifications, investigation and filling out required documentation, you record particulars in the company journal. You would be correct to use which flagging column entry?
A: ACC

B: APACC

C: COLL

D: MVA

A

C
Explanation:
This stands for “collision.”
CJ p 8 COLL

39
Q

Units are taking up from a 2nd alarm in a peaked roof Queen Anne private dwelling. Due to the heavy body of fire, the Incident Commander had ladder company members ventilate the roof to relieve interior conditions and facilitate the extinguishment of the fire. Which tactic mentioned below was incorrect?
A: The first hole was made at the main gable.

B: Members operated the power saw from the basket of the tower ladder.

C: After the hole was cut, the ceiling on the top floor was pushed down with a 6-foot hook.

D: Members realized that if they were to cut the roof with an axe, the opening would be limited to the members reach, but would generally be about 2’ X 3’.

A

C
Explanation:
C. …10’ hook

“A 6’ hook (10’ HOOK FOR QUEEN ANNE) SHOULD BE BROUGHT TO THE ROOF TO PUSH DOWN THE CEILING ON THE TOP FLOOR AFTER THE ROOF HAS BEEN CUT.”

TOUGH QUESTION. JUST BE AWARE OF ANY VARIATIONS MENTIONED BASED ON TYPE OF BUILDING OR OCCUPANCY

Private Dwellings Ch 4: 6.3

40
Q

The Drag Rescue Device (DRD) can be beneficial in the removal of a distressed member. Once packaged, the distressed member can be securely moved in a number of ways. Which way is not in accordance with Department policy?
A: When using the DRD only horizontal drags should be attempted.

B: The member can be dragged horizontally by grasping the DRD with one hand and the distressed members left shoulder strap with the other hand.

C: The member can be lifted vertically by grasping the DRD only and a second rescuer grasping the legs of the distressed member.

D: The member can be carried horizontally, or up or down stairs, with one rescuer grasping the DRD only and a second rescuer grasping the leg-straps of the distressed member.

A

C
Explanation:
Also….The member can be carried horizontally, or up or down stairs, with one rescuer grasping the DRD with one hand and the distressed member’s left shoulder strap with the other, while a second rescuer assists by grasping both leg straps of the distressed member.
***Read these 2 sections carefully. You’ll hear the word conflict from many and many other state it is 2 different operations and not a conflict. We recommend you know both cold and let the others protest it if it is on your test:
MMID Ch 3 Add 4 3.1 states members “can be carried horizontally, or UP or down stairs.”
MMID Ch 3 Add 2 2.1 states the “DRD is designed for horizontal drag only. No other application shall be attempted.” Also the note on 2 states “members should not be dragged up stairs utilizing the DRD.”
MMID Ch 3 Add 4 3.1