Bx Test 17 Flashcards
Class 2 multiple dwellings create interesting scenarios for the OV firefighter. Which of the following additional considerations is INCORRECT regarding the 1stArriving Outside Vent position at fires in these buildings?
A: The OV should anticipate elevators equipped with firefighter service in these buildings.
B: In any instance where the OV operates on the exterior of the building, the 1st Ladder Officer must be informed.
C: If elevator operations are not required for an upper floor fire, the OV shall report to their officer and team up with the inside team and assist with the search of the fire apartment.
D: If elevator operations are not required for an upper floor fire, the OV may be assigned to locate secondary entrances to the fire apartment and/or additional stairways servicing the fire apartment/floor.
A
Explanation:
FFP – MULTIPLE DWELLINGS – CLASS 2 BUILDINGS
A - INCORRECT – The OV should anticipate elevators NOT being equipped with Fire Service. 8.8.3
B – Correct – 8.8.3
C – Correct – 6.14.3 / 8.8.3
D – Correct – 8.8.3
After a very busy day tour in a great Engine Company, you reflected on the runs you had, which included a response to a Buckeye pipeline leak, a Brush fire, and an Iroquois pipeline leak. Of the runs listed below, choose the one you operated correctly at.
A: While shutting down the Buckeye pipeline manual valve found on the shipper’s line located at the Long Island City terminal, you ensured your FFs to turn the valve 84 half turns (clockwise)
B: You received a ticket to respond on the 2nd alarm to the Buckeye pipeline leak while shopping for the meal and returned to quarters to pick up the required additional cans of foam
C: On your way to the Iroquois pipeline leak, you remember that the pipeline carries natural gas that under pressure in a gaseous state, its non-toxic, its lighter than air, it can be an asphyxiant as it displaces oxygen, and its combustible in concentrations from approximately 5-15 percent
D: You were the first arriving engine company to a fast moving brush fire and hooked up to a hydrant, and concentrated on mobility for the initial attack
C
Explanation:
A- 24 full turns (48 half turns) for shippers lines…..42 full turns (84 half turns) for manual valves …..AUC 149 sec 2.3.2
B- Additional cans of foam are required if responding from quarters. Engine companies out of quarters receiving a notification to respond to a 2nd alarm for a pipeline leak must not return to quarters for the additional cans of foam….AUC 149 sec 4.12
C- And it will naturally disperse into the atmosphere. Its odorless and colorless in its natural state, however mercaptan is added to give the gas an odor for detection purposes….AUC 150 sec 1.1
D- AUC 151 sec 5.4.2…..If exposures are involved, then you would hook up to a hydrant and protect exposures…sec 5.4.2
On the new Motorola APX8000XE radios, the time is shown on the main display of the radio. A newly promoted officer should know which point below to be incorrect?
A: Time must be set to 24 hour time.
B: Time must be reset twice yearly for Daylight Saving Time.
C: Time does not need be reset when the radio is returned from repair.
D: Once time is set, removing the battery will not affect the time.
C
Explanation:
Time MUST be reset when the radio is returned from repair.
Comm 11 Add 5
The roof firefighter from Ladder 199 was discussing access to the roof during operations at Class 2 Buildings following roll call. Which choice is CORRECT as usually not a viable option for the roof firefighter to get to the roof at a fire in one of these dwellings?
A: Adjoining Building
B: Aerial Ladder
C: Fire Escape
D: Open Stairs
B
Explanation:
FFP – MULTIPLE DWELLINGS – CLASS 2 BUILDINGS.
B IS CORRECT – 8.8.4 – Access to the roof in priority order. Aerial ladder is the 3rd option and usually not a viable option.
Access to roof in order of priority:
1- Remote/unaffected Stair with Roof access
2- Adjoining Building
3- Aerial Ladder (usually not a viable option)
4- Fire Escape
5- Open Stairs (see note in Section 8.8.2)
You’re the officer of the third engine company to arrive at the scene of a fire on the parlor floor of a 3-story brownstone building. You are ordered to stretch the second hoseline. You would be correct to stretch this line to what location?
A: The second line must be stretched to the parlor floor to back up the first line.
B: The first floor to ensure the fire did not start below.
C: The top floor to extinguish any fire that may be extending above.
D: Exposure 2 or 4 depending on the fire spread.
A
Explanation:
A. Fire on an upper floor of a brownstone: the second line is stretched through the front door on the second (parlor) floor to back up the first hoseline.
THERE IS NO MENTION OF THE SECOND LINE BEING STRETCHED TO THE FLOOR ABOVE AT A FIRE ON AN UPPER FLOOR OF A BROWSTONE
Brownstones 3.3
There are many companies in the FDNY designated as a “Water Rescue Company” that may be called upon to rescue numerous stranded civilians who become trapped due to rising, but non-flowing, flood waters, referred to as still water. From the choices listed below, choose the only correct statement made about these companies.
A: The 14’ boat issued to these companies will not be issued oars or a motor
B: When the Water Rescue Company is a Ladder Company, an additional Ladder Company will be dispatched for assistance
C: When the Water Rescue Company is a Engine Company, a Ladder Company will be dispatched for assistance
D: The maximum number of persons that a Flat Bottom Boat can hold is 4
A
Explanation:
AUC 159 add 7
A- NO OARS NO MOTOR….The intent is for members to walk the boat into the flooded areas where the depth of water permits…sec 2
B- When the Water Rescue Company is a Ladder Company, an Engine Company will be dispatched to transport the Flat Bottom Boat….sec 4.2
C- When the Water Rescue Company is an Engine Company they will transport the Flat Bottom Boat, and a neighboring Engine Company will be dispatched to assist in operations….sec 4.3
D- Maximum is 3……sec 4.5.picture
At cellar fires, it is often necessary to cut the first floor to provide the necessary means of ventilation, so that the engine companies may advance their lines for extinguishment. The cut should be made as near to ___________.
A: the walls as possible and near doorways and aisles
B: the walls as possible and away from doorways and aisles
C: the windows as possible and near doorways and aisles
D: the windows as possible and away from doorways and aisles
D
Explanation:
The cut also may be used for getting water on the fire with bent tips, distributors or cellar pipes.
Txpyr 5.5.22
There are a number of rules that apply to mutual exchanges. Which choice below is CORRECT according to the PA/ID on mutual exchange guidelines?
A: Applications for mutual exchanges shall be submitted at least 2 days in advance of the first date involved
B: Mutual exchanges of tours shall be completed within a 15-day period subsequent to the first date involved
C: Under normal circumstances, members should not owe or be owed 8 or more mutual exchange of tours. This includes self-mutuals.
D: Approved mutual shall be voided if either member will be on any type of leave or detail for which the member has been notified more than 5 days prior to the first date of mutual.
D
Explanation:
PA/ID 6/72 – MUTUAL EXCHANGE GUIDELINES
D IS CORRECT 1.7
A – At least 3 days in advance 1.5
B – Within a 30 day period
C – This EXCLUDES self-mutuals. 1.9
Which of the following uses of a portable ladder at a fire operation is described correctly?
A: At a building without a front fire escape, when the fire is in the cellar, first floor and/or second floor, raise the portable ladders adjacent to and above the fire area.
B: At a multiple dwelling with a front fire escape, if the fire escape becomes overcrowded, a portable ladder should be raised to the second balcony at a point on the opposite side as the drop ladder.
C: In the situation described in choice B, If more relief is required, another portable ladder should be raised to the first balcony.
D: Portable ladders must be lashed to the fire escape for safety.
A
Explanation:
B. At a multiple dwelling with a front fire escape, if the fire escape becomes overcrowded, a portable ladder should be raised to the FIRST balcony at a point on the opposite side as the drop ladder.
C. In the situation described in choice B, If more relief is required, another portable ladder should be raised to the SECOND balcony.
D. IF TIME AND CONDITIONS PERMIT, lash the ladders to the fire escape for safety.
Portable Ladders 10.1
The Rapid Response Vehicle (RRV) that is equipped with a MDT, will be identified in the CADS system in which correct choice?
A: RRV027
B: R027
C: R27
D: RRV27
B
Explanation:
AUC 159 add 8 sec 3
4 door/4 wheel drive apparatus equipped with a MDT will be identified in the CADS system as follows: R…..example R027
2 door/2 wheel drive apparatus without a MDT will be designated by the associated SOC Support Ladder Company…example Ladder 126 2nd piece will be designated SSL-126 when called over the Department radio
Also check out section 4…has been asked on previous exams
AUC 159 add 8 is new as of 11/20/2019
When an Incident Commander at any operation determines that compromised FDNY Dispatch communications may endanger FDNY members or the public at large, the IC should implement “encrypted dispatch” communications. The IC shall notify that Borough Dispatcher that they need to activate the “primary” encrypted dispatch channel which is?
A: CITYWIDE FIRE 3
B: CITYWIDE FIRE 4
C: HT-9/TAC SEC
D: HT-10/CMD SEC
A
Explanation:
CITYWIDE FIRE 3. The IC should be guided by the Borough Dispatcher if directed to the “secondary” encrypted dispatch channel CITYWIDE FIRE 4.
Note: Dispatch frequencies CITYWIDE FIRE 3 or CITYWIDE FIRE 4 may be accessed in either DISPATCH Zone C or FIRE DISPATCH B/U Zone. The CITYWIDE FIRE 3 & 4 are NOT strapped like the “tactical” encrypted channels. That is the channels are not always encrypted. Activating encryption is accomplished by the use of the concentric switch at the base of the channel selector knob on top of the HT.
HT-9/TAC SEC (Tactical), and HT-10/CMD SEC (Command) are Strapped (Encryption is always active). No further action is required to encrypt communications.
Comm 11 Add 3 3
Which of the following is INCORRECT regarding Operations during fires in vacant buildings?
A: Members shall not conduct searches on the floors above the fire until all visible fire has been knocked down and the IC has conducted a size up and risk assessment.
B: Primary searches should generally be conducted after all visible fire has been knocked down and the IC has completed a size-up and risk assessment.
C: Because of questionable roof support systems, the potential for rapidly expanding fires, and the falling hazards caused by pre-existing holes, roof openings, deteriorated parapet walls, etc, members shall not operate on the roof of these buildings.
D: When a vacant building is heavily involved in fire on arrival, hose streams should be placed between the involved building and the most severe life exposure.
C
Explanation:
FIREFIGHTING PROCEDURES – VACANT BUILDINGS
C IS INCORRECT – 5.5 Members should operate with due regard for safety
A – 5.4
B – 5.3
D – 5.2
Listed below are certain safety precautions members shall take when operating an aerial ladder. Which one is incorrect?
A: Never move the truck with the stabilizers in contact with the ground.
B: Never move the truck with the ladder raised.
C: Always properly secure hose lines to the ladder, taking care that hose straps do not interfere with the operation of the ladder sections.
D: If a firefighter is to climb the aerial ladder at the start of an operation, he or she shall be in position on the turntable before the aerial ladder is to be raised and rotated.
B
Explanation:
B. Never move the truck with the ladder raised TO ONE SIDE. RETRACT THE SECTIONS SUBSTANTIALLY AND TURN THE LADDER PARALLEL TO ITS BED.
TIGHT POINT BUT THE AERIAL LADDER CAN BE MOVED WITH LADDER RAISED. JUST NOT WITH IT RAISED TO ONE SIDE
Aerial Ladders 8.20; 8.21; 8.22; 8.25
Company officers should be familiar with the process of identifying hazardous materials. Of the following choices, which is described correctly?
A: In a Truck, the “bill of lading” is kept in a locked compartment in the back of the cab.
B: On a Railroad, the “waybill” is carried by the conductor in the caboose or engine.
C: On an Aircraft, the “air bill” is kept by the pilot or co-pilot.
D: On a Ship, the “cargo manifest” is kept by the Captain.
B
Explanation:
In a Truck, the “bill of lading” is kept in the cab within reach of the driver.
On a Railroad, the “waybill” is carried by the conductor in the caboose or engine.
On an Aircraft, the “air bill” is kept by the pilot.
On a Ship, the “cargo manifest” is kept by the master or first mate.
HM 2 4.4
The companies of Battalion 59 recently operated at the scene of a collapse of a vacant building where during the operation several squatters were removed from sections of the debris pile. The companies were back on the scene to do a critique of the operation and several markings were discovered. Which choice is CORRECT regarding the department’s policy for marking buildings?
A: A search assessment marking was visible on the building. It was a 2’x2’ marking that formed the letter X when completed.
B: A primary vacant building marking 2’x2’ remained visible alongside the front entrance.
C: A secondary vacant building marking depicting an X remained visible alongside the collapsed bulkhead.
D: A search assessment building marking depicting a large V, 2’ in height remained where a victim was confirmed.
A
Explanation:
FFP COLLAPSE ADDENDUM 2 – CROSS REFERENCE VACANTS
A IS CORRECT 2.1
B – Primary vacant building markings are 18”x18”. Vacants 1.3.2
C – All vacant building markings must be identified with an X in a box. 1.3.1
D – Victim confirmed is depicted by an V with a circle around it. 5.3 addendum 2
You’re the first arriving ladder company officer operating at a fire on the top floor of an old law tenement. You’re conducting overhaul and have the following thoughts. Which one is incorrect?
A: After the fire has been knocked down it is the responsibility of the first ladder company to arrive to determine if the fire is extending and where it is extending.
B: The ceilings should be opened first starting at a point where the fire was most intense and working towards a clean area of ceiling space.
C: Steel columns will only be found in New Law Tenements, not Old Law Tenements. Boxed out areas around a steel column create a natural void.
D: If a boxed out protrusion on a wall contains a steel column and was involved in fire, then the entire length of this void will have to be examined.
C
Explanation:
C. Steel columns may be found in New Law Tenements OR OLD LAW TENEMENTS.
Ladders 3: 7.2.1; 7.2.2; 7.2.6