FT 9/21 Flashcards
The search for life should start immediately upon entering which of the following, and then followed by searching for the extension of fire? 1. The fire apartment, 2. Areas adjacent to the fire apartment, 3. Areas above the fire apartment or fire floor Select one: a. 1, 2, 3 b. 1, 2 c. 2, 3 d. 1, 3
C
(TB Search—6.3, 6.4) (If entry can be made and the search conducted without the protection of the hoseline, members may attempt to locate and contain the fire area of origin, and then start the search for life from this point. If untenable, move in behind the engine company advance and search from behind the hoseline.)
The correct answer is: 2, 3
The determining factor as to whether the entrance door to the fire apartment will remain open or closed while a search is being conducted is whether or not?
Select one:
a. There is a known life hazard
b. There is a significant wind condition
c. The Engine has a charged hoseline and is ready to advance
d. There is fire showing from failed windows
C
(TB Search—9.10.1)
The correct answer is: The Engine has a charged hoseline and is ready to advance
When a ladder company enters an apartment to search without a charged hose line at the entrance door, they should leave a \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_ outside the doorway to indicate the apartment they are searching? Select one: a. Hydraulic FE tool b. Halligan c. Axe d. 6’ hook
A
(TB Search—9.10.1)
The correct answer is: Hydraulic FE tool
An Engine Officer reaching an apartment entrance door with a charged line where a ladder company is searching inside that apartment should not open that door until its opening is approved by?
Select one:
a. The Engine Officer can make this judgment based on existing conditions
b. The ladder officer inside the apartment
c. The Incident Commander
d. The firefighter inside the apartment maintaining control of the door
B
(TB Search—9.10.1)
The correct answer is: The ladder officer inside the apartment
The preferential order of removing a victim from a fire building is?
Select one:
a. Interior stairs, Horizontal exits, Fire Escape, Ladders, Life Saving Rope
b. Interior stairs, Ladders, Horizontal exits, Fire Escape, Life Saving Rope
c. Interior stairs, Horizontal exits, Ladders, Fire Escape, Life Saving Rope
d. Interior stairs, Fire Escape, Horizontal exits, Ladders, Life Saving Rope
A
(TB Search—13.2)
The correct answer is: Interior stairs, Horizontal exits, Fire Escape, Ladders, Life Saving Rope
When using the Pressurized Water Extinguisher at a fire, it would be incorrect to state that?
Select one:
a. A straight stream should be directed at the base of the fire
b. A gloved finger placed lightly over the nozzle tip can help produce a fine spray
c. A fine spray pattern can obtain maximum cooling effect and extend the application time
d. A fine spray produced by a gloved finger placed lightly over the nozzle tip at fires is particularly useful when there are detectable thermal drafts
D
(TB Tools 1—2 D) (Use ONLY on small or smoldering fires with no detectable thermal draft)
The correct answer is: A fine spray produced by a gloved finger placed lightly over the nozzle tip at fires is particularly useful when there are detectable thermal drafts
Which point below concerning the Pressurized Water Extinguisher is incorrectly stated?
Select one:
a. The pressurized water extinguisher shall be inspected daily and after each use
b. If the hydrostatic test date of a pressurized water extinguisher is greater than 3 years, place the extinguisher out of service
c. Water extinguishers should never be used on or about energized electrical fire situations
d. The extinguisher should be slowly pressurized to 100 psi using a pressurization source that is never set higher than 125 psi
B
(TB Tools 1—3) (5 years)
The correct answer is: If the hydrostatic test date of a pressurized water extinguisher is greater than 3 years, place the extinguisher out of service
Which point below about the KO Curtain is accurately stated?
Select one:
a. It should be inspected daily
b. It has four, 3/8 inch diameter; 15 foot long fire proof ropes at each corner of the curtain
c. It is 10 feet wide by 12 feet long
d. The Battalion should be contacted for a replacement KO Curtain
B
(TB Tools 2—1, 3.1, 6.3) (8’ x 6’, Weekly at MUD, Division should be contacted)
The correct answer is: It has four, 3/8 inch diameter; 15 foot long fire proof ropes at each corner of the curtain
Which point indicated below regarding the Fire Window Blanket is not correctly stated?
Select one:
a. When a replacement Fire Window Blanket is required, the company officer should contact the Division
b. The bottom of the blanket is weighted to facilitate positioning
c. Members assigned to the floor below must be in place prior to deploying the blanket
d. A spotter shall be designated by the assigned unit or IC and be equipped with a HT and binoculars obtained from the battalion vehicle
A
(TB Tools 3—3.2, 3.4, 4.3) (Contact R & D during business hours, Contact SOC during non-business hours)
The correct answer is: When a replacement Fire Window Blanket is required, the company officer should contact the Division
Fire Window Blankets shall be inspected? Select one: a. Daily b. Each tour c. Monthly d. Weekly
D
(TB Tools 3)
The correct answer is: Weekly
Portable generators shall be inspected weekly for \_\_\_\_\_ minutes, and during this time, all lights shall be operated for \_\_\_\_\_ minutes to test them for proper working order and test the generator under load? Select one: a. 15, 5 b. 10, 5 c. 15, 10 d. 20, 5
A
(TB Tools 4—3.8.2)
The correct answer is: 15, 5
Please pick from the choices below when evacuation would not be best considered?
Select one:
a. The potential for a discharge is small, and it has not taken place
b. People not yet in the path of a release will be threatened by changing conditions.
c. The discharge has taken place but people are sufficiently protected to permit time for evacuation.
d. There is an immediate danger of fire or explosion.
A
(ERP) (The potential for a discharge is great, it has not taken place, and there is time to relocate people.)
The correct answer is: The potential for a discharge is small, and it has not taken place
Sheltering-In-Place is the preferred alternative when the hazardous material displays all the following characteristics except?
Select one:
a. Small quantity solid or liquid leak.
b. Totally released and dissipating.
c. Low to moderate flammability.
d. A migrating vapor of low toxicity and quantity and people are safer indoors than outside.
C
(ERP 9.5.5 C) (Low to moderate toxicity)
The correct answer is: Low to moderate flammability.
Safe Refuge Area should occur in which zone?
Select one:
a. Support Zone / Cold Zone
b. Decontamination Zone
c. Exclusion Zone / Hot Zone
d. Contamination Reduction Zone / Warm Zone
D
(ERP 9.6.3)
The correct answer is: Contamination Reduction Zone / Warm Zone
The Casualty Collection Point is located in the?
Select one:
a. Support Zone/Cold Zone
b. Decontamination Zone
c. Contamination Reduction Zone/Warm Zone
d. Exclusion Zone/Hot Zone
A
(ERP 9.6.4)
The correct answer is: Support Zone/Cold Zone
During a hazardous materials incident the first arriving ladder company will be divided into teams. Team 1 from the first arriving ladder is responsible for? Select one: a. Hazard identification b. Information resources c. Site access control d. Evacuation to gross decon
A
(ERP 11.1)
The correct answer is: Hazard identification
During a hazardous materials incident the first arriving ladder company will be divided into teams. Team 2 from the First arriving ladder is responsible for? Select one: a. Evacuation to gross decon b. Site access control c. Hazard identification d. Information resources
D
(ERP 11.1)
The correct answer is: Information resources
During a hazardous materials incident the second arriving ladder company will be divided into teams. TEAM 1 from the Second arriving ladder is responsible for? Select one: a. Site access control b. Evacuation to gross decon c. Information Resource d. Hazard identification
C
(ERP 11.2)
The correct answer is: Information Resource
During a hazardous materials incident the second arriving ladder company will be divided into teams. Team 2 from the Second arriving ladder is responsible for? Select one: a. Initial exclusion zone b. Evacuation to gross decon c. Hazard identification d. Information resources
A
(ERP 11.2)
The correct answer is: Initial exclusion zone
During a hazardous materials incident which Engine Company is normally responsible to assist with site access control? Select one: a. 1st due engine b. 2nd due engine c. 3rd due engine d. 4th due engine
B
(ERP 12.2)
The correct answer is: 2nd due engine