Runbacks Flashcards

1
Q

What are all of the Intermediate Runbacks?

A
  1. Loss of 1 Reactor Feed Pump AND Reactor water level < level 4 (+30”)
  2. Loss of 1 Circ Water Pump with 4 Circ Water Pumps running AND Condenser pressure > 4.5” HgA.
  3. Loss of 1 Secondary Condensate Pump WITH total feedwater flow ≥ 73.65% AND 2 or more feed pumps in service.
  4. Loss of 1 Primary Condensate Pump WITH total feedwater flow ≥ 73.65% AND 2 or more feed pumps in service.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are all of the Full Runbacks?

A
  1. Reactor water level < Level 3 (+12.5”)
  2. Total feedwater flow < 22% for > 15 seconds
  3. Loss of 1 Circ Water Pump with 3 or less Circ Water Pumps running AND Condenser pressure > 5.8” HgA.
  4. Loss of Stator Water Cooling for 27 sec(15+12)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the purpose and setpoint of the Loss of 1 Reactor Feed Pump AND Reactor water level Runback and what is its associated setpoints?

A

Intermediate Runback
Reactor water level < level 4 (+30”)
Purpose: Reduction of power to maintain RPV water level.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the purpose and setpoint of the Loss of 1 Circ Water Pump with 4 Circ Water Pumps running AND Condenser pressure Runback and what is its associated setpoints?

A

Intermediate Runback
Condenser pressure > 4.5” HgA.
Purpose: Reduction of power to limit condenser vacuum degradation.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the purpose and setpoint of the Loss of 1 Secondary Condensate Pump WITH total feedwater flow XX % AND 2 or more feed pumps in service Runback and what is its associated setpoints?

A

Intermediate Runback
total feedwater flow ≥ 73.65%
Purpose: Reduction of power to maintain RPV water level.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the purpose and setpoint of the Loss of 1 Primary Condensate Pump WITH total feedwater flow XX % AND 2 or more feed pumps in service Runback and what is its associated setpoints?

A

Intermediate Runback
total feedwater flow ≥ 73.65%
Purpose: Reduction of power to maintain RPV water level.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the purpose and setpoint of the Reactor water level Runback and what is its associated setpoints?

A

Full Runback
Reactor water level < Level 3 (+12.5”)
Purpose: Maintains adequate Recirc and jet pump pump NPSH at low level conditions.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the purpose and setpoint of the Total feedwater flow Runback and what is its associated setpoints?

A

Full Runback
Total feedwater flow < 22% for > 15 seconds
Purpose: Maintains adequate Recirc and jet pump pump NPSH at low feedwater flow conditions

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the purpose and setpoint of the Loss of 1 Circ Water Pump with 3 or less Circ Water Pumps running AND Condenser pressure Runback and what is its associated setpoints?

A

Full Runback
Condenser pressure > 5.8” HgA.
Purpose: Reduction of power to limit condenser vacuum degradation

(Bypassed when bypass switch is in “RECIRC RUNBK BYPAS” (Pictured at right))

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the purpose and setpoint of the Loss of Stator Water Cooling Runback and what is its associated setpoints?

A

Full Runback

How well did you know this?
1
Not at all
2
3
4
5
Perfectly