Radwaste Flashcards
What are the 5 systems of liquid radwaste?
Equipment Drains (CRW)
Floor Drains (DRW)
Regenerate Waste (ARW)
Chemical Waste
Detergent Waste
Describe the purpose of the equipment drains.
- High purity waste. Processed via precoat filter and deep bed demineralizer.
- After recirc and sample analysis, water can be sent to the river, the CST, or back for reprocessing.
- DW sumps are cooled by chill water and RB sumps are cooled by RACS to prevent flashing in the sumps.
Describe the purpose of the floor drains.
- Low purity waste. Processed via precoat filter and deep bed demineralizer.
- After recirc and sample analysis, water can be sent to the river, the CST, the Waste Neutralizing Tanks (WNT) for segraegation, or back for reprocessing.
Describe the purpose of regenerative waste.
High conductivity waste. Slowly drained to floor drain system.
Describe the purpose of the chemical waste.
Very high conductivity waste. Slowly drained to the regenerate waste system.
Describe the purpose of the detergent waste.
Decontamination and general cleaning water from inside RCA. Discharged to river via mech filter.
What are the different ways we process radwaste?
- Filtration (via precoat filter or mechanical fiber filter)
These are PCIS Isolations → - Demineralization (mostly via deep bed demineralizers)
- Precoat filters provide limited demin capability
- Evaporation (evaps no longer in use)
- Vendor supplied casks dry liquid and solid rooneywaste for transport and burial
What important functions are lost during a loss of radwaste?
- RWCU: loss of blowdown path and backwash capability.
- RHR: loss of torus letdown and RHR warmup.
- Condensate: Inability to rinse condensate polishers. Loss of CST makeup.
What important functions are lost during a loss of radwaste?
- RWCU: loss of blowdown path and backwash capability.
- RHR: loss of torus letdown and RHR warmup.
- Condensate: Inability to rinse condensate polishers. Loss of CST makeup.
how is solid radwaste(ie spent resin) processed?
- RWCU – sent to Clean up phase separator
- Floor drain, equipment drain, and FPCC precoat resin – Sent to the waste sludge phase separator
- Floor Drain, equipment drain, and FPCC polisher resin – Sent to spent resin tank.
- Dry solid Rooneywaste is collected, packaged, and sent off site for incineration or burial.
What are the isolation signals for drywell equipment & floor drains?
Level 2 (-38”)
1.68# DW
RB Hi Rad (1x10-3ucu/cc)
*Isolates F019 & F020 for the Equip drains and F003 & F004 for the Floor drains. Each drain also has one AOV which will open when a pump is running.
What are the 3 ways to process radwaste?
- Filtration (via precoat filter or mechanical fiber filter)
- Demineralization (mostly via deep bed demineralizers)
- Precoat filters provide limited demin capability
- Evaporation (evaps no longer in use)
- Vendor supplied casks dry liquid and solid rooneywaste for transport and burial
What is the impact of losing radwaste?
- RWCU: loss of blowdown path and backwash capability.
- RHR: loss of torus letdown and RHR warmup.
- Condensate: Inability to rinse condensate polishers. Loss of CST makeup.