Nuclear Boiler Instrumentation - .5 Flashcards

1
Q

Describe Narrow Range Level Detectors

A

1) 0” to +60”
2) Calibrated hot at 1000#, 135°F in Drywell, and 75°F in Rx building.
3) If indicated level is steady, actual level goes down with Rx pressure going up.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Describe Wide Range Level Detectors

A

1) -150” to +60”
2) Calibrated hot at 1000#, 135°F in drywell, and 75°F in Rx building.
3) ECCS initiation goes off of wide range instruments.
4) Largest disparity between indicated and actual level occurs when cooling down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Describe Upset Range Level Detectors

A

1) 0” to +180”
2) Calibrated hot at 1000#, 135°F drywell, and 75°F Rx Building
3) Indicates higher when cooling down

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Describe Shutdown Range Level Detectors

A

1) 0” to 400”
2) Calibrated cold at 0#, 120°F Water, 80°F drywell, and 75°F Rx building.
3) Indicates lower when cooling down because it is calibrated colder, more dense, higher D/P.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Describe Fuel Range Level Detectors

A

1) -311” to -111”
2) Calibrated for accident: no jet pump flow, 0# in vessel and drywell, saturated steam water mixture, and 75°F in Rx building.
3) When in refueling, the absence of the Fuel Pool Low Level Alarm indicates that level is >22’ 5” above the RPV flange.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Wide Range Pressure Detectors

A

0-1200# OR 0-1500#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Narrow Range Pressure Detectors

A

850-1050#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Low Range Pressure Detectors

A

0-50#

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Describe PAMS Recorders

A

1) Channels A&B - They have the shortest vertical run of piping in the drywell and are less affected by accident conditions. Preferred instrument during accident. (See EOP Caution 1)
2) Shifts to fast speed on Level 3 (12.5” OR 1037#). Can return to slow speed by pressing button next to recorder when above 12.5” or below 1037#.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Level 8

A

+54”
(4 turbine trips)
-Main Turbine trip (NR)
-RFP Turbines trip (NR)
-HPCI Turbine trip (WR)
-RCIC “Trip” (WR). (F045 shuts => secures steam)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Level 7

A

+39”
-Hi Level Alarm (NR)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Level 5/6

A

+35”
-Normal Operating Level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Level 4

A

+30”
-Low Level Alarm
-Interim (45%) Recirc Runback (IF concurrent w/ a RFP trip)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Level 3

A

+12.5”
-Rx Scram
-Lowers FWLC setpoint set down (14”)(.5 sec TD)*
-Full recirc runback
-ADS Confirmatory signal
-RHR sample and discharge to RW isolation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Why is the FWLC setpoint lowered during Level 3?

A

Prevent over feeding on a scram/low level.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Level 2

A

-38”
-RCIC & HPCI initiate.
-RRCS Input: ARI, RPT (9 sec TD), start 3.9 minute SLC timer.
-A&B SACS pumps start
-RBVS isolates, supply and exhaust fans trip.
-FRVS fans start
-Radwaste supply and exhaust fans trip
-EIAC trips
-PCIS isolations
-NSSSS Isolations: RWCU F001/F004, Recirc sample 4310/4311, TIPS retract and isolate.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What are the PCIS Isolations for Level 2?

A

-RC boundary leak detection system
-H2/O2 analyzers
-CPCS/N2ME/DW purge valves
-H2 recombiner
-TWCU
PCIG (minor)
-Drywell floor and equipment drains

18
Q

Level 1

A

-129”
-CS & LPCI initiate
-Signal to ADS Logic
-CRD trips
-A-D EDG, SACS, and SSW start.
-PCIG trips
-FPC, PCIG, TACS SACS cross ties close
-RACS pumps A&B Trip, SSW to RACS Isol.
-RACS to Turb and Aux bldgs isolates
-TSC Chillers Start
-CREF aligns and both loops start
-Non 1E MCCs Trips
DW Coolers Trip
MT LO Pumps and Lift Pumps Trip
RFP LO Pumps Trip
-NSSSS Isolations
MSIVs and MSIV Drains (F016 & F019)
-PCIS Isolations
Chilled Water to DW
RACS to Recirc Pump Pedestal
CRD to Recirc Seal Purge

19
Q

What happens if drywell temp is hotter than vessel temp?

A

Indicated water level will indicate higher due to boiling in the reference leg.

20
Q

Rx Flange level

21
Q

Steam Lines Level

22
Q

Top of Moisture Separators level

23
Q

TAF Level

24
Q

Level Zero

25
Q

BAF

26
Q

The pressure drop across the steam dryers can cause…

A

A 7” level difference inside core shroud-downcomer.

27
Q

A-E SRVs Pressure setpoint

28
Q

G, J, L, R, and P SRVs Pressure setpoint

29
Q

F, H, K, and M SRVs Pressure setpoint

30
Q

RRCS Hi Pressure (ATWS) Pressure setpoint

31
Q

Lo-Lo Set Actuation (Lo-Lo Set Armed, SRV P Open) Pressure setpoint

32
Q

SCRAM Pressure setpoint

33
Q

Hi Pressure alarm

34
Q

Lo-Lo set H opens Pressure setpoint

35
Q

Lo-Lo Set P closes Pressure setpoint

36
Q

Lo-Lo set H closes Pressure setpoint

37
Q

MSIVs close w/ Mode switch in run (NSSSS)

38
Q

Core Spray Injection Permissive Pressure setpoint

39
Q

LPCI Injection Permissive Pressure setpoint

40
Q

HPCI Isolation Pressure setpoint

41
Q

RHR SDC High Pressure Isolation setpoint

42
Q

RCIC Isolation Pressure setpoint