What are the ECCS Acceptance Criteria?
A
- Cladding temperature does not exceed 2200°F.
- Cladding oxidation shall not exceed 17% of cladding thickness.
- Collable geometry.
- H2 generation from zirc/water reaction shall not exceed 1% of the amount generated if all clad reacted.
- Long term cooling.
2
Q
What is the DBA LOCA criteria?
A
- Reactor initially at 102% rated thermal power (3917 MWth).
- Loss of offsite AC power
- Instantaneous, complete circumferential break of a recirculation pipe at the suction nozzle.
- Loss of a channel A DC source (disabling HPCI, one loop of Core Spray, and one loop of LPCI)
Note: The initial reactor power used in the DBA LOCA Containment analyses is 105% (4031 MWth).
3
Q
What are the ECCS systems and what are their ratings?
A
- HPCI – Designed for breaks < 1” in diameter.
- 3000 gpm - A CS line, 2600 gpm – A FW line, Initiates -38”, 1.68#, manual
- Core Spray – Two 100% capacity loops.
- 3175 gpm per pump (6350 gpm per loop), 461 psi inj open permissive, 380 psi shutoff head.
- LPCI – Four 100% capacity loops.
- 10000 gpm (x4), 450 psi inj permissive, 340 psi shutoff head (171 psi for rated flow). -129”, 1.68#
- ADS – Assist HPCI by depressurizing the plant in the event of a small break LOCA where HPCI cannot maintain level.
- A thru E SRV’s used to depressurize RPV on -129 and 1.68 psi drywell (or timer)
4
Q
How much time do you have to respond to a DBA LOCA?
A
10 mins.