Waste Gas (WDS) Flashcards

1
Q

What is the Waste Gas Design?

A

Adequate processing of waste gases from both plants assuming continuous operation with 1% fuel defect

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What does the WGC inlet isolation valve do?

A

Prevents short-circuiting gas thru the standby WGC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What does the WGC Moisture Sep Unloader valve do?

A

Prevents compressor from starting under load

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What does the WGC Moisture Sep Gas Recycle Valve do?

A

Controls vent header pressure by opening to recycle waste gas from moisture separator back to vent header

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the interlock associated with the GDT Inlets?

A

Only 1 can be open at a time

“Break before make”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

When will the I/S GDT swap to the Standby GDT?

A
  • Hi-Hi oxygen (from AOM)
  • In Service GDT gets to 100#

only swaps if a standby tank is selected

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

At what constant pressure does RRV-305 (Waste Gas Release pressure Ctrl Valve) maintain the inlet pressure to RRV-306?

A

5 psig

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What does RRV-306 (Waste Gas Release Flow Ctrl valve) do?

A

Manually positioned to control release FLOW rate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What will trip RRV-306 (Waste Gas Release Flow Ctrl valve) closed?

A
  • Loss of both U1 AX Fans
  • High Rad on U1 or U2 Vent Stack Rad Monitors (VRS-1500/2500)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What does the AGA do?

A

Monitors GDTs for flammable mix of hydrogen and oxygen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What does the AOM do?

A
  • Monitors oxygen at discharge of compressors (moisture separator)
  • Isolates the inservice GDT on a High - High Oxygen alarm
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Per TRO 8.7.13, Gas Storage Tanks, why do we restrict that gas storage radioactivity?

A

Ensures that during an uncontrolled release of the tanks’ contents, with the resulting total body exposure to an individual at the nearest site boundary will not exceed 0.5 rem

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What interlock does RRV-306 have to open?

A
  • At least 1 AX must be running**
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Where does the AOM sample the waste gas header

A

Discharge of the moisture separator on the WGC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

If VRS-2500 loses power, what happens if you are doing a gas release?

A

RRV-306 will close; AX fan will still be running

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are the alarms for the AGA?

A

High O2 – 2.5% O2
High H2 – 4.0% H2

17
Q

What are the alarms for the AOM?

A
  • High O2 – 2.5% O2
  • Hi-Hi O2 – 2.7% O2 (Closes GDT inlet on I/S GDT)
18
Q

What is the normal waste gas vent header pressure?

A

Between 1.3 - 2.0 psig

19
Q

What is the maximum limit of radioactivity in the gas storage tanks per TRO 8.7.13 (Gas Storage Radioactivity)?

A

43,800 Ci noble gas