What are the only permissives that are “lit” at 100% power?
P-6 and P-10
Which permissives don’t have a physical status light?
P-4 and P-14
When is the P-6 status light lit, and what is the function?
ANY Intermediate Range NI greater than or equal to E-10 Amps and rising permits the MANUAL block of the SR High Flux Trip
When does the P-6 status light go out, and what is the function?
When BOTH Intermediate Range NIs are < 6E-11 amps and lowering. This prevents/defeats the manual block of the SR High Flux Trip
When does the P-10 status light get lit, and what are the functions?
2/4 Power Range NIs Greater than or equal to 10%. This permits the manual block of:
1. PR High Flux Trip, Low Setpoint
2. IR Trip
3. IR Rod Stop
and also:
4. Resets P-7
5. de-energizes the SR NIs (backup)
When does the P-10 Status light go out, and what are the functions?
3/4 Power Range NIs < 10%. This prevents / defeats the manual blocks of:
1. PR High Flux Trip, Low Setpoint
2. IR Trip
3. IR Rod Stop
and also:
4. Inputs into P-7
When does P-12 status light get lit, and what is function?
2/4 Loop Tavg less than or equal to 541 degrees F. This allows a manual block of SI due to low steam line pressure and blocks all steam dumps.
If combined with high steam flow, there will be a Main Steam Line Isolation
When is the P-12 status light clear and what is the function?
3/4 Loop Tavg > 541 degrees F. This prevents / defeats the manual block of SI due to low steam line pressure
Under what conditions is P-4 met, and what are the functions?
Both reactor trip breaker A and bypass Breaker A open.
OR
Both Reactor Trip Breaker B and Bypass Breaker B open.
This seals in FWI from SI / Hi-Hi SG Level and permits a manual block of auto SI signals.
If combined with Low Tavg, there will be a FWI
When is P-4 no longer met? And what is the function?
Either Reactor Trip or Bypass Breaker racked in and closed. This prevents/defeats the manual block of SI
When is the P-7 status light lit? What is the function?
3/4 PRs < 10% AND 2/2 Turbine 1st stage pressures < 10%
This permits the AUTO block of the 6 “at power” reactor trips
When is the P-7 Status light not lit? What is the function?
2/4 PRs >10% OR 1/2 turbine 1st stage pressures > 10%
This prevents/defeats auto block of at power reactor trips, with the exception of the turbine trip
What are the 6 at power reactor trips that are auto blocked when P-7 Status light is lit?
- Pressurizer Pressure Low
- Pressurizer Water Level High
- RCS Loss of Flow
- Undervoltage on RCP Buses
- Under Frequency on RCP Buses
- RCP Breaker Position
When considering other Permissives, what will make P-7 status light be lit?
Reset of P-10 and actuation of P-13
What makes P-8 status light get lit, and what are the functions?
3/4 PRs less than or equal to 29% permits the auto block of Rx Trips due to a single loop low flow trip AND Turbine Trip