Other Important Shit Flashcards

1
Q

Which unit can open ZMO-10 and 20?

A

Either Unit

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Which unit can close ZMO-10 / 20

A

BOTH units are needed to close these valves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

If there is a CRCV Fire in Unit 1, what fire protection is available?

A

Auto Halon

Manual CO2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If there is a CRCV Fire in Unit 2, what fire protection is available?

A

Auto Halon

Manual CO2

Auto Water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is special if Halon is actuated at the cylinder?

A

Extended discharge cylinders won’t acutate

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the Containment Chill Water Purpose?

A

Provide 55*F water to containment loads

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What happens if you use disable on the HMI for containment chill water?

A

You shutdown the entire system (chillers and pumps)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What makes up the Hi-Storm 100 System?

A
  1. Hi-Storm Overpack
  2. MPC
  3. Hi-Trac Transfer
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the purpose of Helium in the dry cask system?

A

Cooling

Inert Atmosphere to prevent chemical reaction

Leak detection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

How does Liquid Release Valve RRV-285 fail on a loss of CA?

A

Closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the inputs to the RCDT?

A

Receives drains from:

Accumulator Drains
XS LD Hx Drains
Regen Hx Drains
RCS Loop Drains
RCP #2 Seal Leak off
Rx Vessel Flange Leakoff
Refueling Cavity

OUTLET OF TANK

RCP #3 Seal Leak off
PRT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

How many Ctmt Sumps are there and what are they?

A
  1. Recirc Sump
  2. Rx Cavity Sump
  3. Lower Ctmt Sump
  4. Pipe Tunnel Sump
  5. Instrument Room Sump
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What goes into the CWHUT

A

Hard piped drains from 609’ and above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What goes into the DWHUT

A

Floor drains from 609’ and above

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What goes into the Clean Waste Sump Tank

A

Hard piped drains from 587’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What goes into the Dirty Waste Sump Tank

A

Floor drains from 587’

17
Q

What goes into the AB Sump

A

573’ Floor Drains

Including Clean and Dirty Waste Sump Tanks overflow

18
Q

What is the purpose of the Waste Gas Release Pressure Control Valve RRV-305?

A

Maintains a constant 5# inlet pressure to RRV-306

19
Q

What is the Waste Gas Release Flow Control Valve RRV-306 used for?

A

Manually positioned to control release flow rate

20
Q

What is the purpose of the Moisture Separator Gas Recycle Valves?

A

Control Vent Header Pressure

21
Q

What is the purpose of the WG Separator Unloader Valve

A

Prevents compressor from starting under load

22
Q

Purpose of WGC Inlet Isolations?

A

Prevents short-circuiting gas thru the S/B WGC

23
Q

What is the design of the Waste Gas System?

A

adequate processing for both plants assuming 1% fuel defects in 1 Unit

24
Q

Which systems / components vent to the waste gas vent header?

A

RCDT

CVCS HUTs

VCT

AGA

PRT

NBAE Vent Condenser

SRST

WG Recycle Lines

Waste Gas Drain Tank Vents

25
Q

What is the purpose of the AGA?

A

Monitors waste gas system tanks for flammable mix of

Hydrogen and Oxygen

26
Q

What is the purpose of the AOM?

A

Monitors OXYGEN at discharge of compressors

27
Q

What is the purpose of the Waste Gas Compressor?

A

Maintain Waste Gas Vent Hdr pressure 1.3 - 2.0# by auto starting and stopping as needed

28
Q

What pressure must the waste gas header be at for the pump to start?

A

< 0.5 #

29
Q

8.7.13 Gas Storage Tanks Basis - Restricting the quantity of radioactivity contained in each gas storage tank provides assurance that in the event of:

A

an uncontrolled release, the resulting total body exposure to an individual at the nearest site boundary will not exceed 0.5 rem