Stator Cooling Water Flashcards

1
Q

What are the SCW pump auto starts?

A
  • Low Disch pressure at 130 psi (U1) and 80 psi (U2)
  • Low Flow at 845gpm (U2 only)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are the Main Turbine and Unit Differential trips associated with SCW?

A

Temperature, flow and pressure trips

  • 2/3 RTDs at 81°C (U1) 95°C (U2) after 5 second delay
  • 2/3 Low Flow at 499 gpm (U1) and 666 gpm (U2)
  • 2/3 Low Pressure at 36 psi (U1) and 28 psi (U2)

(Each auto trip will actuate)

  • Main Turbine Trip after 10 seconds
  • Unit Differential Trip after 30 seconds.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What cools the SCW coolers?

A

TACW

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

How is the SCW maintained to prevent water leaking in the Generator?

A

SCW pressure is maintained 3-4 psi less than machine gas pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Why is the SCW maintained 3-4°C warmer than Cold Gas Temp?

A

Prevent moisture from forming on the outside of the Stator Water Teflon tubes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is the auto makeup to the SCW system?

A

Demin Water

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the purpose of the SCW system?

A
  • Removes heat from the Main Gen stator armature conductors
  • Designed for continuous operation and must be in service to allow operation of the Main Generator
  • Cools U2 Output Bushings
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How to you prevent channeling of the SCW Deionizer?

A

Maintain less than 100 gpm flow through the deionizer

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What temp must you maintain in the deionizer to prevent resin breakdown?

A

Less than 120°F to prevent breakdown of the resin

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Why does the SCW system have deionizers?

A

To remove conductivity so transfer of electricity thru water is not possible

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the backup source of makeup water to the SCW system?

A

Condensate (Manual only) (HWP Discharge)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where is the U1 SCW tank vented to?

A

Atmosphere

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

How does U2’s SCW Tank differ from U1s SCW Tank?

A

Unit 2 SCW tank has H2 cover pressure instead of being vented to atmosphere

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What does 1-CRV-640 (SCW Reg Valve) do in U1 only?

A
  • Maintains Main Gen water inlet pressure at about 3# < machine gas pressure
  • Mechanical stops prevent flows < 340 gpm (25#) and > 550 gpm.
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

How will a loss of CCRP affect the SCW Sys?

A

A loss of CCRP blocks the SCW High Temp Turbine Trip

When power is restored, the block is removed 15 seconds later.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Which SCW Trips are blocked to allow Unit Backfeed operations?

A

Low pressure and Low Flow

17
Q

What are the conductivity numbers associated with SCW?

A
  • Conductivity at 9.9 mho/cm (reduce load)
  • MANUAL TRIP at 18 mho/cm conductivity
18
Q

What is the purpose of the teflon connectors in the SCW System?

A

Provide electrical insulation between the stator bars and the system piping