What is the purpose of the Containment Chill Water System?
To provide 55°F chilled water to containment loads
What is the Containment Chill Water head tank normal makeup source?
Demin Water
What will happen if you select DISABLE on the HMI?
It will shutdown the entire system
What is the emergency make up water source to the CHW head tank?
NESW
What is the normal power supply to Unit 1 Containment Chill Water System?
Transformer 10 cross-tied through U2 Switchgear
What is the normal power supply to Unit 2 Containment Chill Water System?
Transformer 10
What temp band do we try to maintain in lower containment?
Between 60°F and 120°F
What temp band do we maintain in upper containment?
between 60°F and 100°F
Which color light requires an operator to don a SCBA if he needs to enter?
Red Light (High Level)
What pressure must be maintained in containment according to LCO 3.6.4 (Containment Pressure)? When is this applicable?
≥ -1.5#
≤ +0.3#
(Modes 1-4)
What must be done per TS LCO 3.6.4 (Containment pressure), Condition A, if pressure is outside the required band?
Restore containment pressure to within limits within 1 hour
When is the plate and frame hx rated for 100% of the system load?
When lake temperature (NESW) is less than 53 degrees