Safety Injection Flashcards

1
Q

What gives a SI Signal?

A
  1. Pressurizer Low Pressure - 1775 psig (2/3)
  2. Containment Pressure High - 1.0 psig (2/3)
  3. S/G Press Low - 500 psig (1/1 on 2 S/G)
  4. S/G Diff Press 1 S/G 100 psid lower than 2 others (2/3)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

A SI Signal also gives what else?

A
  1. Phase A
  2. CVI
  3. FWI
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What Equipment gets autostart signals on a SI Signal?

A
  1. EDG
  2. CCPs
  3. SI Pumps
  4. RHR Pumps
  5. CCW Pumps
  6. MDAFPs
  7. NESW Pumps
  8. Both units ESW Pumps
  9. Both units CRP Fans
  10. AES Fans
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Which valves close on a SI Signal in the Charging System?

A
  1. CCW to LD Hx
  2. VCT Outlet Valves QMO-451/452 after suction source is realigned.
  3. CCP ELOs for 2 secs then look at pressure
  4. Charging Header Iso Valves QMO-200/201
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Which valves open on a SI Signal in the Charging System?

A
  1. RWST Suction to CCPs IMO-910/911
  2. BIT Inlet Valves IMO-255/256
  3. BIT Outlet Valves ICM-250/251
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

How do the CCW Hx Outlet valves change on a SI Signal?

A

Open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

How do the ESW from CCW Hx Outlet valves change on a SI Signal?

A

Throttle Open to ~ 5500 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

How do the CCW from RHR Hx Outlet valves change on a SI Signal?

A

Throttle Open to ~ 3000 gpm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What are the auto actions on the ECCS Systems on a SI?

A
  1. CCPs autostart
  2. Charging pump realigns to RWST
  3. CCP ELOs close for 2 secs
  4. Charging header isolates
  5. BIT valves open
  6. SI pumps start
  7. RHR pumpms start
  8. Accumulator outlet valves get open signal
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Is the CCW to the RHR Hx actually needed for the initial injection phase ?

A

No. It’s actually a flow path to protect the CCW pump on the SI so flow has some where to go.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

How will the CRP system realign on a SI?

A

Damper 1, normal outside air closes

Damper 2, alternate outside air part opens

Damper 3, recirc stays open

How well did you know this?
1
Not at all
2
3
4
5
Perfectly