Bleed Steam/FW Heater Drains Flashcards

1
Q

What are the HDP trips?

A
  • Extreme Low Level in associated heater
  • Turbine Trip
  • Overload/Overcurrent
  • HMO-564 AND HMO-563 fully closed (Middle pump only)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is required to start the M HDP?

A

HMO-564 OR HMO-563 required to be full open (interlock)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Why are there check valves in the bleed steam lines?

A

Prevents turbine overspeed caused by backflow of steam/water to turbine

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What determines which Heater Lo-Lo level will trip the Middle HDP?

A

The positions of the Suction Cross-ties

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

When do the HDP ELOs open?

A
  • Opens when HDP Discharge flow is < 1250 gpm back to the condensers (2100 gpm for unit 2)
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Does #6 FW Heater have an alternate drain?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Where does the #6 FW Heaters receive drains from?

A

RCDT and HPT

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Where do the #5 FW Heaters receive drains from on Unit 1?

A

MSDT, HPT, and # 6 Heater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where do the #5 FW Heaters receive drains from on Unit 2?

A

HPT and #6 Heater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where do the #4 Heaters receive drains from on U1?

A

LP Turb

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Where do the #4 Heaters receive drains from on U2?

A

MSDT, HP Turb, and #5 Heater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What will a high high lvl in any heater cause?

A

Isolated heat input to associated heater

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

What heaters do the HDPs take a suction from on U1?

A

The #5 FW Heaters
- N HDP from 5B
- M HDP from 5A or 5B
- S HDP from 5A

This makes sense directionally in the plant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What heaters do the HDPs take a suction from on U2?

A

The #4 FW Heaters
- N HDP - 4A
- M HDP - 4A or 4B
- S HDP - 4B

This makes sense directionally in the plant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When will Bleed Steam Isolation Valves auto close?

A

Turbine Trip and Hi-Hi Heater Level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

When do FW Heater Alternate Drains auto open?

A

High Heater level

17
Q

How will the Heater Alt drains fail?

A

Open

18
Q

How will the Heater Norm drains fail?

A

Closed

19
Q

What does a high DCTTD indicate?

A

Low Heater level

20
Q

Where do the #3, #2 and #1 Condensate Heaters receive drains from and where do they drain to?

A
  • Receive drains from the LP Turbines
  • Drain to the next lower Condensate Heater or Condenser (Alt)
  • # 1 heaters drain to an external drain cooler
21
Q

Where do the drain coolers drain to?

A

Condensers

22
Q

Which feedwater heaters do NOT have alternate drains?

A

6 Heaters for both Units

#4 Heaters for Unit 1

23
Q

How much of the MFP Suction flow are Heater Drain Pumps good for?

A

25%

24
Q

What are the power supplies for the Heater Drain Pumps?

A

RCP Buses
North - D
Middle - B
South - C

25
Q

What do you do if a HDP Trips?

A

Lower Turbine Load by 30 MW at 30 MW/Min