SFP Flashcards

1
Q

What are the SFP Pump trips?

A
  • Load Shed
  • Load Conservation
  • Overload/Overcurrent
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Per TS 3.7.15 (Fuel Storage Pool Boron Concentration), what is the boron concentration required in the SFP?

A

≥ 2400 ppm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Per TS 3.7.14 (Fuel Storage Pool Water Level), what is the minimum water level allowed in the SFP?

A

23’ above top of fuel (Basis: Iodine removal)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the power supplies for the SFP Pumps?

A

11C for North SFP Pump
21C for South SFP Pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How do we keep from inadvertently draining the SFP?

A

No Gravity Drains
SFP Pp Suctions 19.5” below surface
Anti-Siphon Holes 4” below surface
Skimmers 6” below surface
Return Lines > 6’ above fuel

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Per TS 3.7.14 A (Fuel Storage Pool Water Level), what is done if the level requirement is not met?

A

IMMEDIATELY
-Suspend fuel movement

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Per TS 3.7.15 A (Fuel Storage Pool Boron Concentration), what must be done if the boron concentration is out of spec?

A

IMMEDIATELY
- Suspend movement of fuel
AND
- Initiate action to restore compliance
OR
- Initiate action to perform fuel storage pool verification

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is a secondary function of the SFP system?

A

clarify and purify the water in the SFP, transfer canal, and purify the RWST

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Where do SFP discharge lines terminate and what do they do to prevent siphoning?

A

Discharge lines terminate no lower than 6’ above the top of the fuel assemblies and anti-siphon holes are located 4” below normal level

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What happens to SFP Cooling on a Phase ‘A’?

A

CCW to the SFP HX Isolates

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

If U1 is providing cooling to the SFP Hx and has a SI, what happens?

A

U2 will need to align cooling through the South Pump

assumes a Phase A signal is also generated

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

What trips a Refueling Water Purification Pump (RWPP)?

A

Load Conservation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Core Alterations are in progress on Unit 2. RCS boron concentration has been verified to be 2360 ppm (two samples analyzed).
The crew is required to …

A

Suspend core alterations and positive reactivity changes. Initiate boration to correct.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What provides inflation air to the SFP Weir Gate?

A

Plant Air system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Will cross-tie of the SFP System through the purification piping prevent boiling?

A

No! Just delays it.

IF makeup is > 175 gpm in addition, MAYBE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are the important design features for the SF Racks and New Fuel Racks in regards to Reactivity IAW TS 4.3?

A
  • **Keff ≤ 0.95 even with unborated water. (0.98 foam)
  • ** 21” Center to center between fuel assemblies (new fuel racks)
  • Nominal enrichment < 4.95% of U-235.
17
Q

How far does the suction for the SFP pumps terminate below the surface?

A

19”

18
Q

What is the primary source of heat production in the SFP?

A

Fission Products

19
Q

With the design features for the SFP, what level is the lowest possible?

A

Never below 629’4”

20
Q

Why is the minimum level of 23 ft above the fuel required per the bases?

A

To meet the assumptions of iodine DF follwoing a fuel handling accident