What is ICM-305/306?
RHR Suction from Recirc
What is IMO-215/225
RWST to CTS Pump
What is IMO-310/320 ?
RHR Suction Valves
What is IMO-330/331 ?
RHR to Upper Spray
What is IMO-340/350 ?
RHR to CCP / SI Suction
What is IMO-262/263 ?
SI Recirc to RWST
To Open the Recirc Sump valve ICM-305, what alignment must you have?
Can’t go onto recirc sump unless your isolated from the RSWT via RHR and CTS suctions
To Open the CCP or SI pp Suction from the RHR Pumwhat alignment must you have?
Can’t supply the CCP or SI pump with water from RHR pump unless you’re on the recirc sump and the SI pump recirc back to the RWST is isolated bc you’d pump your recirc sump to RWST
To open RHR Spray valves, what alignment must you be in?
Must be on recirc sump
To Open your RHR pump suction valve, what alignment must you have?
Can’t be on the recirc sump, trying to Spray, or trying to supply CCP / Si with water from RHR
What is the normal position for RWST Valves to CCP Suction IMO-910 and 911 and what auto opens them?
Parallel, normally-closed, motor-operated Automatically open on SI signal Automatically open on Refueling Water Sequence: low-level (2.5%) in VCT
How to the CCP Emergency Leak-off Valves (ELO) QMO-225 and 226 work on a SI?
Close on SI signal Open after2 sec time delay with SI signal present and RCS pressure above 1825 PSIG. Close if RCS pressure drops below 1812 PSIG
CCP Emergency Leak-off Valves (ELO) QMO-225 and 226 continue to cycle on pressure after a SI until?
SI signal is reset Control switch placed in PULL TO RESET position - resets SI seal-in circuit
East CCP Emergency Leak-off Valves QMO-225 receives pressure signal from
NPP-151
West CCP Emergency Leak-off Valves QMO-226 receives pressure signal from
NPP-153
What are BIT Inlet Valves, IMO-255 and 256 Normal position and auto alignment?
Parallel, normally-closed Open on SI signal to provide injection flowpath to RCS cold legs through BIT