SBGT Flashcards
What is the purpose of the Standby Gas Treatment System?
Maintain small negative pressure of 0.25”WC in RB under secondary containment isolation condition to minimize ground level release of airborne radioactivity.
What is the flow through SBGT (total)?
4000scfm primary train;
300scfm cooling flow;
Total 4300normal;
4000cfm +10% is tech spec limit
How is the SBGT sized for flow and air purification?
Sized to provide 1 air change per day in RB
Where does SBGT discharge to?
310’ chimney
Where does SBGT take suction from?
RB Vent (between Rad Element & RB Vent exhaust dampers)
U2/3 DW and Torus (only if <62psig)
U2&3 HPCI gland exhauster
U2&3 DW & Torus via APCV
What elements are included in the SBGT Air Filter Unit and what is their purpose?
Demister - removes bulk moisture to lower humidity
Heater - to raise temp and humidity to improve efficiency
Rough Filter - to remove large particulates
HEPA Filter - remove 99% particulates >=3micron
Charcoal filter - removes 95% of iodine at flow of 4000scfm
After filter - removes free charcoal that has come dislodged.
When does the SBGT Heater start?
When adequate flow is achieved.
What supplies actuation force for SBGT Flow Control Dampers?
A Train from U2 IA
B Train from U3 IA
What supplies air signal to the A Flow transmitter? B? What happens if both fail?
Both are supplied by U2 IA.
A fail safe accumulator is provided to ensure they fail open on loss of IA or loss of control power
What provides power to A Train SBGT electrical components? Control power? B Train?
A Train from MCC 29-9; Control power from U2 ESS
B Train from MCC 39-2; Control power from U3 ESS
What are the positions for the SBGT Inlet Dampers?
Normally closed, auto open on initiation signal
What are the SBGT Outside Air Supply Dampers?
They are normally open and provide for removal of decay heat on SBGT train which is not running.; On system initation, damper for running train closes.
What provides motive force for ambient decay heat removal in SBGT?
Dampers on standby train is open, running train fan creates suction flow of 300scfm through filter unit and through crosstie to running train
Where does removed moisture from SBGT demister route and how is the secondary containment boundary maintained?
Removed moisture to Radwaste. Filled loop seals maintain secondary containment.
What is the purpose of the SBGT Electric Heater?
Raises air temp by 14deg to lower humidity to 70%.
Auto start when flow >2600scfm