Equipment Drains Flashcards
What is the purpose of Radwaste?
Receive potentially contaminated water wtihin the plant, ‘process’ it in batches, send those batches to above ground sample tanks, and, if aparameters allow, route the sample batches back to 2/3 CSTs for re-use
What is the purpose of the Equipment Drain System?
Receive high quality liquid waste from anticipated leak off points and process it for reuse
What is the Waste Collector Tank? Capacity? Location
It collects the water from the equipment drain systems, anticipated, clean, leakoff points.
33,000gal
RW Basement
What are the inputs for the Waste Collector Tank?
RBEDT DWEDS DWFDS TBEDS Waste Demin Off-Standard Off-Gas Filter Building PDT Pp Off Gas Drain Pump Bed Plate Drains
How many pumps are there for the Waste Collector Tank and where are they?
there are 2. Located in RW Basement
What is the Waste Surge Tank? Location? Capacity?
Provides a place from which to batch river discharges.
Also large volume for water in excess of Waste Collector Tank Capacity
Located in Tank Farm
77,000gal
How many Waste Surge Tank Pumps are there? Where are they?
- RW Mezz
How many Waste Collector Filters are there? Where are they?
What are their flow limits?
2 - normally 1 in service.
Located in vaults on RW Mezz
Limited to a max DP of 20psid w/ nominal flow of 200gpm
These remove particulates from the water from WCT or WSgT
What is the Waste Demin Purpose? LOcation?
Flow Limit?
Mixed resin Demin to remove ionic impurities from filter effluent
Located on RW Basement
Limited to max DP of 40psid
What are the Waste Sample Tanks?
How many are there?
Where are they?
Capacity?
Provide a place from which to collect water processed from the Waste Filter, MR and ALPS
Located in Tank Farm
There are 3 - Each 33,000gal
What is the Resin Cleaner Sludge Tank?
Location?
Capacity?
Collects Inputs from Ultrasonic Resin Cleaner
RW Basement
27,500gal
What is the Waste Filter Sludge Tank?
Location?
Capacity?
Collects inputs from WCF backwashes, Fuel Pool Filter Backwash and WCT & WSgT blow down
RW Basement
27,500 gal
What is the Floor Drain Filter Sludge Tank?
Location?
Capacity?
Collects inputs from all filter dome vents, FDCT blowdown, and the A/B Waste Neut Tank Blowdown
RW Basement
27,500gal
What is the Spent Resin Tank?
Location?
Capacity?
Collects inputs from the fuel pool demins, reactor water cleanup demins, condensate demins, max demins, waste demin and mix and hold tank
RW Basement
15,000gal
What is the RW Sparging system?
Air Compressor system used to supply mixing air for sampling