Fuel Pool Cooling Flashcards
WHat is the purpose of FPC?
To provide high clariity filtered demin water to pools and remove decay heat released by irrdiated fuel
Maintain pool temp below 141F (half offload (150F full offload)) to minimize release of IODINE
Remove radioactivity release to water during normal handling of fuel
MAINTAIN AIRBORNE RAD LEVELS w/in limits using ventilation
What are the Tech Spec required water levels for fuel pool?
19ft above fuel (32’-3”)
What is the purpose of the Rx Cavity and Refuel Seals?
DW to RB bellows seals accommodate differential expansion between DW and RB during heatup and cooldown
THIS IS PART OF SECONDARY CONTAINMENT
DRAIN TO RBEDT
Rx to DW bellows seal accommodate differential expansion between Rx and DW during heatup and cooldown
Primary Containment boundary
Drains to DWEDS
Where does the Dryer-separator pit fill from?
Hotwell and condensate OR Core Spray/LPCI
Where does the DW to RB Bellows Seal drain to? how is leak detected?
to RBEDT - detected via flow switch and sight glass
flow switch initiates 902-3 panel alarm at 5gpm
Where does the RPV to DW bellows seal drain to? How is leak detected?
Draings to DWEDS. Flow switch sends signal to 902-4 panel - 1gpm
What is the High alarm for Fuel Pool Storage?
37’11”
If the Rx Cavity were to drain without the gates in place, waht is the lowest level water can reach?
1.3 ft above fuel
What are teh FPC Skimmer Surge Tanks?
Take water from the Fuel Pool (and other pools if connected) via weirs and provide NPSH to FPC pumps
This is where condensate transfer make up connects
No isolation
What is the makeup to the FPC surge tanks?
Cond. Transfer
How is level maintained the same in the two FPC Surge Tanks?
Equalizing line
What are the alarms for the FPC Surge Tanks and where are the instruments?
ALL INSTRUMENT ON A TANK Hi Temp Below Normal Lvl - 110" Level Lo - 41" Fuel Pool Pump Trip - 17"
What can be done if Condensate transfer is not available to FPC Surge tanks?
BY HOSE - makeup from: (in order of preference):
1 ) Contaminated demin hose station
2) Clean demin hose station via clean demin pumps
3) Clean demin hose station w/ iso condenser M/U Pumps
4) Fire water via hose
5 Hi volume makeup from U2 only condensate Pp discharge header
How many Fuel Pool Cooling Pumps are there? how many normally in service?
Power SUpplies?
2 - 1 normally in service
2A - Bus 28
2B - Bus 29
Where are the FPC pumps controlled from?
RW Control room or local control panel