Condensate System(CM) Flashcards
What are the primary purposes of the Condensate System?
- Take Condensate from the Condenser Hotwell
- Purify and filter for chemistry requirements
- Reheat to improve efficiency
- Deliver it to the suction of the feedwater pumps for feeding the steam generators
What are the secondary purposes of the Condensate System?
- Provide a cooling medium for:
A. Condenser Steam Air Ejectors(CSAE)
B. Gland Seal Condenser(GS)
C. Steam Generator Blowdown(BB) heat exchangers - Provide water to Auxiliary Feedwater Condensate Storage Tank(CACST) for temperature and chemistry requirements
- Provide water from Hotwell Pumps for:
A. Turbine Exhaust Hood Spray(TS)
B. Main Feedwater Pump seals(CL)
C. Condensate Booster Pump seals
D. “C” Heater Drain Tank Pump Tandem Seals***
E. Condensate Storage System(CS) loop seals
F. Main and CFPT Condenser seal trough makeup - Provide water from CBPs for “C” Heater Drain Tank Pump mechanical seals***
What is the primary purpose of the Condensate Storage System(CS)?
Provide a readily available source of deaerated water for makeup to the condenser.
What are the secondary purposes of the Condensate Storage System(CS)?
- Alternate supply of makeup to the Auxiliary Feedwater System(CA)
- Collect and store miscellaneous drains
- Supply Auxiliary Electric Boiler Feedwater System
- Receive condenser water on high hotwell pump pressure or high hotwell level
Where does water that’s condensed in three sections of the main condenser accumulate?
All of the condensing sections of the main condenser allow water to be piped back to the ‘A’ Hotwell which extends under the ‘B’ and ‘C’ sections.
How does the water flow from the ‘B’ and ‘C’ Condensers to the A Condenser?
The ‘B’ and ‘C’ sections are connected to the ‘A’ Condenser via Cascade Pipes.
What is the precaution associated with the Cascade Pipes?
If the condenser cascade pipes have been drained, they are filled prior to filling the condenser hotwell. This prevents damage due to floating the cascade pipes.
What is the system designator for the Condensate System?
CM
What is the normal range for Hotwell level?
5.5 to 5.8 feet
How is Hotwell normal level controlled?
The Hotwell normal makeup valve, CS-47, aligns automatically to makeup to the Hotwell as level lowers.
Where does normal makeup water to the Hotwell come from?
The Upper Surge Tank(UST)
When is Emergency Hotwell Level Control used, and what valves provide this function?
- Emergency makeup is not used during normal operating conditions and are maintained closed in Mode 1 and 2. They are used in accordance with procedural guidance during Mode 3 and 4.
- Valves: CS-33 and CS-57
Where does Emergency Makeup to the Hotwell come from and where can it be discharged?
- Emergency makeup water comes from the Upper Surge Tank.
- Water can either be discharged above or below the normal Hotwell level. The line that discharges above the normal Hotwell level is used for deaeration when vacuum is established.
How does the Hotwell Normal Makeup Valve, CS-47, fail on a loss of air?
CS-47 fails closed on a loss of air
How does a Auxiliary Feedwater(CA) auto start affect the Hotwell Normal Makeup Valve, and why?
- The normal makeup valve will fail closed on a CA auto start
- This ensures that the volume in the UST is available for CA
How is the Hotwell Normal Makeup Valve reset following a CA auto start?
One control board reset button per train must be depressed to restore the valve to its normal makeup duties
What affect does a simultaneous under-voltage of TA, TB, and TD have on the Hotwell Normal Makeup Valve?
A simultaneous undervoltage on all three Hotwell Pump buses causes the auto makeup feature to be blocked. When the undervoltage condition clears, the blocking signal clears, and the valve resumes normal makeup duties without operator assistance.
How do the Hotwell Emergency Makeup Valves, CS-33 and CS-57, operated to control level?
The valves open sequentially i.e. CS-33 will open fully, then CS-57 opens.
How do the Hotwell Emergency Makeup Valves, CS-33 and CS-57, fail on a loss of air or power?
Both valves will fail closed on a loss of air or power.
What is the design/capacity of the Hotwell Pumps?
- 4 stage centrifugal, vertically mounted
2. 50% capacity, 12720gpm
What system provides cooling to the Hotwell Pump motors?
Recirculating Cooling Water(KR)
What is the power supply for the Hotwell Pumps?
HWP A - TA
HWP B - TB
HWP C - TD
What system provides seal water to the Hotwell Pumps, and when?
- Seal water for the Hotwell Pumps is initially supplied from the Demineralized Water System(YM)
- Following the start of the first Hotwell Pump the seal water is shifted to water from the pump discharge.
What is the purpose of the Hotwell Pump Suction Vent Valve?
The suction vent valve continuously vents back to the condenser to ensure the piping is maintained full of water.
What is the purpose of the Hotwell Pump Discharge Vent Valve, and when does it operate?
- The discharge vent valve will open when the pump is off, and closes 30 seconds after a Hotwell Pump start.
- The discharge vent ensures the pump casing remains full of water in the event that air is sucked through the shaft seal.
What is the order for operating the Hotwell Pump suction and discharge valves?
The Hotwell Pump suction valve is opened before the discharge valve, and closed after the discharge valve to prevent over-pressurizing the suction piping.
What is the interlock between the Hotwell Pump and the Hotwell Pump Discharge Valve?
- The Hotwell Pump will not start if the discharge valve is closed.
- The discharge valve cannot be closed when the Hotwell Pump is running.
What will cause a Hotwell Pump to automatically start?
- A full load rejection if the turbine load is greater than 56%
- A loss of one main feed pump turbine if turbine load is greater than 56%
- Condensate Booster Pump suction pressure lowers to 75psig
What will cause a Hotwell Pump to automatically trip?
The “Windmill” Protection Circuit
What is the “Windmill” protection circuit initiate conditions and when is the protection invoked?
- Initial conditions:
A. CF pump suction valves open
B. Less than 900psig S/G inlet pressure
C. CF pump oil pump in operation - Protection invoked when oil pressure falls below 4.0psig and will cause:
A. HWP trip
B. CBP trip on signal from HWPs being tripped
What is the logic required for starting the first Hotwell Pump?
The following valves must be closed as part of the electrical interlock:
- CM-42 and CM-186, Polisher Bypass Valves
- All 5 Polisher Effluent Isolation Valves
- CM-878, Seal Supply Header Isolation Valve
- CM-83, Load Rejection Bypass Valve
CM-35, Hotwell High Level Control Bypass and CM-877, System Slow Fill Valve are only procedural requirements and not required for the electrical interlock