WEEK #7 WEEK OF 03/08/13 PART I – FFP – ROW FRAME BUILDINGS PART II – DUNN – CHAP. #14 & 15 PART III – AUC's #300, 301 & 306 PART IV – COMMUNICATIONS MANUAL CHAP. #9 & Add #1, 2 & 3 PART V – TB – FOAM {Pgs 22 – 31} INSTRUCTOR: AC RON SPADAFORA Flashcards
PART I – FFP – ROW FRAME BUILDINGS PART II – DUNN – CHAP. #14 & 15 PART III – AUC's #300, 301 & 306 PART IV – COMMUNICATIONS MANUAL CHAP. #9 & Add #1, 2 & 3 PART V – TB – FOAM {Pgs 22 – 31}
1 A Captain of a ladder company at a 2-story residential building sees smoke pushing from
the eaves. While ordering two firefighters to pull plaster on an exterior wall, the officer notices
the second floor resting on a ledger board. This construction feature is indicative of what type of
construction? (Addendum 1, Figure 9)
a platform frame
b plank and beam
c balloon frame
d post and frame
- C
2 A building with three front windows per floor and one apartment going from front to rear
with no rear fire escape is known as what type row frame building? (5.1.2)
a Taxpayer
b Old Law Tenement (OLT)-type
c Brownstone-type
d Single Room Occupancy (SRO)
- C
3 Name the salient feature common to all row frame buildings, regardless of variations in
design: (5.2.2)
a skylight in the rear
b vinyl siding
c common cornices
d common cockloft
- D
4 Choose the correct statement regarding row frame buildings? (5.2.6-5.2.9)
a access to the roof from the interior is via a stair housed by a bulkhead
b cellars may run under more than one building
c light and air shafts are non-existent
d commercial occupancies are commonly found on the upper floors
- B
5 According to FFP, what are the major faults in the construction of row frame buildings as it
pertains to fire and fire spread? (6.2)
a Large amount of combustible materials used in the construction and lack of fire stopping
b Lightweight non-combustible materials and single pane windows
c Heavy timber trusses and bay windows
d Numerous fireplaces and dry rot
- A
6 The danger of collapse of sidewalls with fires in row frame buildings is a factor deserving
consideration. This is especially true during what condition? (6.3)
a when the sidewalls are filled with brick noggin
b when the sidewalls are parged with plaster
c when fire escapes are illegally installed on the sidewalls
d when buildings within the row have been demolished
- D
7 In general, an officer of the second arriving ladder company for a top floor fire in a
Brownstone-type row frame building would be incorrect in ordering members to perform what
action listed below: (7.2, 8.4, 10.2)
a search operations on the top floor
b check exposures for fire extension
c check rear of the fire building for victims
d reinforce laddering the building
- A
8 Where should the second arriving ladder company officer be positioned at a top floor fire in
an Old Law Tenement-type row frame building? (8.5, 10.1)
a at the fire apartment on the top floor
b on the roof of the fire building
c in exposure 2 or 4 with two members of his/her company
d at the adjoining apartment on the top floor of the fire building
- D
9 Members working with a search line under the direction of an officer are said to be under
what kind of supervision? (9)
a Immediate
b Functional
c Synergistic
d Situational
- B
10 For Brownstone-type row frame building fires, top floor VES is mandatory under what
circumstances? (9)
a Height of the building is less than 30 feet and the ceilings are low
b Fire denies use of interior stairs and there is no fire escape
c Roof size-up determines the need for a hose-line to protect exposures
d Building has been vacant for quite some time and is boarded up
- B
11 During VES, why should the windows directly over the main entrance to a Brownstonetype
row frame building be initially avoided? (9)
a they are very large and a firefighter can easily get disoriented
b they are connected in railroad fashion to other rooms deeper in the building
c they open into a small room and egress may be cut off
d they commonly have large openings in the floor
- C
12 Roof ventilation is critical for firefighting operations. Regarding order of preference, what
is the primary way the first arriving Roof firefighter of a rearmount apparatus should attempt to
access this area? (9)
a Aerial ladder
b Second arriving aerial ladder
c Adjoining building
d Interior scuttle ladder
- A
13 What subsequent action should a first arriving Roof firefighter take upon completion of
roof duties at a fire in an OLT-type row frame building? (9)
a descend the aerial and team up with LCC for top floor VES
b operate as per Ladders 3
c drop down to top floor via the scuttle ladder
d move to the adjoining building and check for fire extension on the top floor
- B
14 A first arriving tower ladder pulls up to a fire on the 3rd floor of a 4-story Brownstone-type
row frame structure. After hearing from the Roof firefighter that his/her assistance is not
required and repositioning the basket for fire floor ventilation, what should the OV firefighter do
next? (11)
a reposition the tower ladder basket to the 4th floor for ventilation
b reposition the tower ladder basket to the top floor of the most severe exposure
c reposition the tower ladder basket back to the roof
d place a portable ladder to the second floor
- A
15 Where should the first arriving OV firefighter of a tower ladder place the basket after
getting the Roof firefighter size-up that his/her help is not needed at a 2nd floor fire in a 4-story
OLT-type row frame structure? (11)
a 3rd floor for ventilation
b top floor for ventilation
c top floor of most severe exposed building for ventilation
d 2nd floor for ventilation
- D
16 When the first to arrive Ladder Company is a tower ladder, the chauffeur will remain on
the pedestal. Therefore, the chauffeur of the second to arrive Ladder Company does not have to
report to the pedestal and may be assigned other duties by the company officer. (12)
a True statement
b False statement
- A
17 An engine company officer is ordered by the IC to stretch a hose-line to the top floor of
Exposure 2 during a working fire in a row of frame buildings. In addition to hose and a nozzle,
what other tool should be taken to the area of assignment? (13.1)
a Life saving rope
b Thermal imaging camera
c Six foot hook
d Standpipe kit
- C
18 Choose the incorrect action taken by engine companies at a cellar fire in a row frame
building: (13.2)
a first line unable to make the cellar via the interior stairs protected the first floor
b second line was stretched to the cellar by way of another interior entrance to extinguish fire
since first line was unable to advance
c first line advanced to top floor after cellar fire had been controlled by second line
d on way to the top floor, members on the first line checked intervening floors for fire
- B
19 Engine companies are arriving to a fire on the 3rd floor of a 4-story row frame building.
The fire building is in the middle of a row of similar structures. What engine company action is
not in accord with firefighting procedures? (13.3)
a first line stretched to location of fire via interior stairs
b second line stretched to Exposure 4 since it was reported fire was spreading into this
structure
c third line stretched to back-up second line in Exposure 4
d third line stretched to back-up first line in fire building
- C
20 When would a “Holding Operation” be employed by fire department units? (13.4)
a top floor fire with flames coming through the roof
b cellar fire with extension into an interconnected cellar of an attached frame
c fire in a common cornice
d building fully involved and fire in Exposures
- D
6.5 Building Fully Involved and Fire in Exposures-Holding Operation
21 Select the most appropriate action for the first arriving engine company to perform for a
fire in a vacant building in a row of occupied frames. (13.6)
a stretch a supply line to front of fire building for a tower ladder; then stretch attack line into
the fire building
b stretch supply line; then stretch attack line to the most severe Exposure
c stretch supply line; then stretch attack line into the rear yard of the fire building
d stretch two attack lines into the fire building
- B
22 A first arriving engine company is confronted with a row frame building fire where the
entire block of buildings are vacant. What action ordered by the engine officer was incorrect?
(13.6)
a Had apparatus positioned for possible use of the multiversal nozzle
b Had a supply line stretched for tower ladder use
c Had an attack line stretched for initial use inside the fire building
d Gave the in-line pumping code signal since nearby hydrants were OOS
- C
23 Why is the degree of fire in the rear of row frame buildings an important factor for the
Chief to determine on arrival? (14.2)
a it will affect accessibility to the rear of the building via the street
b it will race laterally into windows and adjoining buildings
c it will mirror the amount of physical punishment being sustained by members
d it will determine whether energy efficient windows have been installed
- B
C. The degree of fire in the rear is a factor, as fire coming out of windows will race
laterally along siding, into the windows of the upper floors and adjacent buildings
24 A BC supervising a drill on operations at cockloft fires in row frame buildings should
correct a company officer for making which inaccurate statement listed below? (14.5)
a When pulling top floor ceilings to check fire extension in the cockloft, it is possible for the
entire ceiling to be blown down
b Small test openings in the ceiling are advisable
c The shorter the cockloft the greater the danger
d Blown down ceilings are caused by banked-up gases igniting rapidly
- C
25 According to FFP, a row frame building with a floor fully involved in fire from the front to
the rear requires what type resources? (14.6)
a 4th alarm assignment, ensure 3 rescue companies are on scene
b 3rd alarm assignment, special call additional battalion chiefs as needed
c 2nd alarm assignment, request the response of an additional deputy chief
d Full 1st alarm assignment, consider calling an additional engine and ladder
- D
- An officer drilling on exterior screened stairways was incorrect to state that they?
a Are the safest type of fire escape
b Have no sliding drop ladder or gooseneck ladder
c Are wide enough for three people to descend side by side
d Are enclosed with a wire screen preventing a fall from outside the fire escape landing
- C
- The hazard of a party wall balcony is?
a Step failure
b Balcony failure
c Falling off the balcony
d Side Rail collapse
- B
- The safest method to remove people from a party wall balcony is?
a via an aerial ladder
b via a portable ladder
c through the designated horizontal exit
d via a portable ladder
- C