URR 5 Flashcards

1
Q

Baseline can be used to eliminate:

A

aliasing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Increasing the ___ allows the display of higher velocities without aliasing

A

scale

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Velocity scale is also known as:

A

pulse repetition frequency

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

varied color assignments to Doppler shifts

A

color map

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

degree of variability of mean velocity at different depths in the sample

A

variance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Typically displayed as a GREEN scale superimposed on the red/blue display

A

variance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

used to highlight flow turbulence

A

variance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

determines if a pixel is displayed as shade of black and white or as a color

A

color priority/threshold

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

____ threshold settings display less color (lower color priority)

A

Lower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

____ threshold settings display more color (higher color priority)

A

higher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Color priority/ threshold is necessary to:

A

minimize color flash/clutter and improper placement of color on vessel walls

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

color sensitivity

A

color persistence

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

used to highlight low velocity flow

A

color persistence

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

determines how much of the previous image data is carried over into the current image frame

A

color persistence

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

____ persistence levels allow prolonged display of color on the image and are preferred for slow moving flow

A

higher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Increasing persistence makes the live image appear ____ and with improved _____

A

smooth
color display

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Increased ____ and ____ levels can aid in the evaluation of heavily calcified arteries

A

persistence
sensitivity

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

_____ persistence levels are preferred for evaluation of blood flow through a moving structure (cardiac applications)

A

lower

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Decrease _____ for improved flow visualization

A

sample size

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

refers to size of color Doppler FOV

A

color sample size

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

____ sample sizes produce better color display

A

smaller

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Increase ____ from improved visualization

A

packet size

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

refers to the number of lines of information in each sample taken

A

color packet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

The ___ lines in the sample, the better the display

A

more

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
____ packet size = better color display
larger
26
There will be NO color displayed with flow ___ degrees to the ultrasound beam
90
27
Flow that is moving in a direction that is ____ to the ultrasound beam will not be detected
perpendicular
28
Flow best detected moving toward and away from the probe or ____ to the beam
parallel
29
Increased _____ settings will display more color on the image.
color priority/threshold
30
Increased color _____ will display a smoother image with reduced image noise, helpful for slow moving flow
persistence
31
Increased _____ settings will eliminate artifactual color display
wall filter
32
2D imaging relies on a _____ of the US beam to the structure (reflection).
perpendicular incidence
33
Color and PW Doppler assess blood flow moving ____ to the US beam
parallel
34
Demonstrates presence of absence of blood flow
power Doppler
35
No flow direction displayed
power Doppler
36
More sensitive to low flow velocities than color Doppler
Power Doppler
37
used to assess organ perfusion
power Doppler
38
Preferred for evaluation of vessels with flow moving perpendicular to the US beam
power Doppler
39
____ sample size for improved flow visualization for power Doppler
Decrease
40
Unrelated to incident beam angle to flow
power Doppler
41
demonstrates flow direction
spectral Doppler
42
Spectral Doppler allows measurement of ____ and _____ flow velocities
peak systolic end diastolic
43
uses a single piezoelectric element to transmit and receive the signal
pulsed wave doppler
44
Pulsed wave doppler is limited by:
vessel depth and flow velocities
45
uses two piezoelectric elements to transmit and receive the signal, not limited by depth or velocity
continuous wave Doppler
46
Continuous wave doppler is limited by:
nonability to determine flow velocity at a specific location
47
Benign mass formation usually demonstrates _____ resistance, ____ velocity flow
moderate low
48
Malignant mass formation usually demonstrates ____ velocity, ____ resistance flow
increased low
49
_____ usually causes decreased resistance to flow in the area affected
infection
50
Always use <___ angle of PW cursor with all arterial exams
60 degree
51
____ sample sizes give more accurate waveforms
smaller
52
The cursor must be ____ to flow to obtain the most accurate velocity measurements
parallel
53
The brightness of the reflection on the Doppler tracing represents:
the number of red blood cells moving at each velocity displayed
54
Doppler gain is ____ related to signal strength.
directly
55
adjusts the displayed amplitude of the reflected sound waves from the flowing blood
Doppler Gain
56
makes the whole waveform brighter or dimmer
Doppler Gain
57
Overgaining on a Doppler exam will cause:
false increase is the peak velocty of the flow
58
any exam that requires measurement of peak flow velocities requires:
angle correction
59
The optimum angle between the cursor and the blood flow is ___ degrees or ___ to the flow.
0 parallel
59
The standard setting for most vascular evaluations is a ___ degree cursor angle.
60
60
Changing the cursor angle changes the velocity calculated from the _____ calculated
frequency shift
61
Overestimating the angle between the cursor and the blood flow will result in:
overestimated velocities
62
Underestimating the angle between the cursor and the blood flow will result in:
underestimated velocities
63
_____ is required for any vessel where velocity calculations are necessary
angle correction
64
adjusts the amount of flow evaluated in a specific location
sample volume size
65
____ samples sizes produce more accurate Doppler information with ____ evaluation of laminar flow and appearance of the spectral window
smaller improved
66
Average size of sample volume is ___-___ mm for arterial evaluations
1 1,5
67
____ sample sizes are helpful for evaluating venous flow and performing volume flow calculations for dialysis access grafts
larger
68
used to evaluate flow in specific locations
sample volume depth
69
Necessary for evaluating arterial stenosis
sample volume depth
70
____ vessels require lower frequency transducers to obtain samples at increased depths
Deeper
71
aka high pass filter
wall filter
72
eliminates low frequency Doppler shifts and high amplitude signals from display
wall filter
73
____, ____, and ____ all involve the incorrect display of lower level Doppler shifts
beam width clutter cross talk
74
_____ the wall filter can reduce the appearance of the "weaker" Doppler shifts on the image
Increasing
75
If the filter setting is too ____ it can remove necessary information from the Doppler tracing
high
75
___ wall filter settings used for venous evaluations compared to arterial evaluations
Lower
76
If the filter settings are too ____, artifactual information from motion/respiration can degrade the image.
low
76
used to demonstrate positive and negative shifts appropriately without aliasing
baseline
77
______ PRF settings used for venous evaluation compared to arterial evaluations
Lower
77
____ the scale allows the display of higher velocities without aliasing
Increasing
78
Standard setting for sweep speed is:
50 mm/s
78
Speed of the spectral Doppler display
sweep speeed
79
Faster sweep speed (100 mm/s) is recommended for precise measurements of _____, _____, and _____ in general.
acceleration time resistive index waveform tracing
80
Slower sweep speeds (25 mm/s) can be useful for evaluating _____ and demonstrating _____
venous reflux time cardiac arrythmias
81
#1 reason for missing a stenosis
improper sample location
82
Always sample the ____ of the vessel EXCEPT when atheroma/stenosis is present
center
83
Take multiple samples in the area of the stenosis in case an _____ is present
eccentric jet
84
Always use <___ degree angle on cursor with any exam where velocity measurements are needed
60
84
Adjust ____, ____, ____ to properly demonstrate waveforms
scale baseline gain
85
____ sample sizes give more accurate waveforms at specific depths
smaller
86
Cursor must be as _____ to flow as possible
parallel
87
highest velocity in artery during cardiac systole
peak systolic velocity (PSV)
87
peak flow velocity in the artery at the end of cardiac diastole
(Peak) end diastolic velocity (EDV)
87
PSV is used to assess for the presence of:
stenosis
87
EDV can be used to assess for presence of ____ and _____
stenosis vascular bed resistance
87
comparison of peak systolic and end diastolic flow velocities and represents the difference between them
resistive index
87
The greater the difference in PSV and EDV, the ____ the RI
higher
87
Transducer frequency is inversely proportional to: a. depth of penetration b. axial resolution c. lateral resolution d. second harmonic frequency
a
87
measured at the highest velocity displayed on the tracing regardless of its occurrence during cardiac cycle
venous flow velocity