Drill Manual - SCBA Flashcards

0
Q

At what PSI does the low bottle switch to the higher bottle?

A

120 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

When the EBSS is hooked up, which bottle will the users begine to use?

A

the low pressure bottle first and then they will switch to the higher

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

At what PSI does the vibralert activate?

A

1100 psi

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When will a vibralert alarm?

A
  • Air cylinder pressure falls below 25% of full (~1100 psi)
  • A failure occurs within the primary reducing system
  • Buddy Breathing with a user that has less than 1100 psi
  • Initially upon opening the cylinder valve, to indicate the system is activated
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What connection is considered the RIC connection?

A

UAC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

How does the UAC work?

A

when connected it equalizes the bottles

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What percent does the vibralert go off?

A

25%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

The fit test is required when?

A

Annually

A weight gain/loss equal to 10% of an employee’s body weight

Facial configuration changes due to, but not limited to, dentures,scarring, reconstructive or cosmetic surgery or pregnancy

Return from a special or administrative assignment where the employee has been away from operations for greater than one year and has not participated in the annual Fit Test program

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

If your air supply is partially or completely cut off?

A

RESIST the urge to remove your face piece 2

OPEN the air cylinder valve completely 3

OPEN the red purge valve completely 4

EXIT the IDLH immediately (consider buddy breathing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

If your face piece is providing free flowing air, check that your purge valve did not accidently open. If not, the SCBA has malfunctioned and you should?

A

1 PARTIALLY CLOSE the air cylinder valve (to regulate and conserve air)

2 OPEN the red purge valve completely (to bypass any regulator malfunction)

3 EXIT the IDLH immediately (consider buddy breathing

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What are the two types of SCBA’s out there?

A

NxG2 and NxG7

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Air filling stations:

What’s the recommended air filling rate per minute?

Not to exceed?

A

300 psi per minute

500 psi do not exceed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

If an alarm caused the compressor to shut down at an air filling station, what action should be taken?

A

call FMO immediately

How well did you know this?
1
Not at all
2
3
4
5
Perfectly